800W~16000W High Frequency Pure Sine Wave Three Phase Online UPS

800W~16000W High Frequency Pure Sine Wave Three Phase Online UPS

bargain

add to cart
Model NO. RH series
Type On-line
Application Industry
Standby Time Standard Machine
Output Capacity Medium Type
Brand Richwin/OEM/ODM/Neutral
Transport Package Carton/Wooden
Origin Shenzhen, China
Phase Three Phase
Protection Overvoltage
Classification Lighting/Power
Standby UPS Sine Wave Output UPS
Equipment Mode Centralized Model
Trademark Richwin/OEM/ODM/Neutral
Specification 282× 145× 220mm5× 220mm220mm5× 220mm
HS Code 8504402000
800W~16000W High Frequency Pure Sine Wave Three Phase Online UPS
RH31 SERIES(10~20KVA)


Function Features

True double-conversion online UPS
DSP technology guarantees high performance
Output power factor0.8
Wide Input voltage range( 3-phase 1 90-520 VAC )
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
ECO mode for energy saving
Generator compatible
Programmable power management outlets
Emergency power off function(EPO)
Charger capacity expansion to 8A for long-run models
3-stage extendable charging design for optimized battery performance
NMP+USB+RS-232 multiple communications
Maintenance bypass available
Optional N+X parallel redundancy
Specification
MODEL RH31-10KS RH31-15KS RH31-20KS
CAPACITY 10000VA/ 8000W 15000VA/ 12000W 20000VA / 16000W
INPUT
Phase 3PH 4W+G
Input VoltageRange 190-520 VAC (3-phase)@ 50% load
305-520 VAC (3-Phrase)@100% load
Frequency Range 46-54Hz or 56-64Hz
Power Factor >=0.99@ Nominal voltage(100% load)
OUTPUT
Phase 1PH 2W+G
Output Voltage 208/220/230/240VAC
Voltage Regulation ±±plusmn;±1%
Frequency Range(Synchronized Range) 46-54 Hz or 56~64 Hz
Frequency Range(Batt. Mode) 50 Hz±±plusmn;±0.1Hz or 60Hz±±plusmn;±0.1 Hz
Current Crest Ratio 3 : 1
Harmonic Distortion <=2% THD(Linear Load), <=5% THD(Non-linear Load)
Transfer
Time
AC to DC Zero
Inverter to Bypass Zero
Waveform(Batt. Mode) Pure Sine wave
EFFICIENCY
To AC Mode 91% 91% 91%
ToBatteryMode 91% 91% 91%
BATTERY
Long-run
Model
Battery Numbers Depending on the capacity of external batteries
Charging Current(max.) 4A 4A
Charging Voltage 218.4VDC±±plusmn;±1%
INDICATORS
LCD UPS status, Load level,Batterylevel, Input / Output voltage, Discharge timer, and Fault indicators
PHYSICAL
Long-run
Model
Dimension ,D××times;×W××times;×H(mm) 442×19imes;19imes;190×318mes;318mes;318
Net Weight(kgs) 28 40 40
ENVIRONMENT
Humidity 20-90% RH@ 0-40ºCordm;Cordm;C(Non-condensing)
Noise Level Less than 50dBA@ 1 Meter
MANAGMENT
Smart RS-232/USB Support Windows@2000/2003/XP/Vista/2008, Windows@7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
*Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.

About Us