10kVA, 15kVA, 20kVA High Frequency Pure Sine Wave Three Phase Online UPS

10kVA, 15kVA, 20kVA High Frequency Pure Sine Wave Three Phase Online UPS

bargain

add to cart
Model NO. RH31-10KS
Type On-line
Application Industry
Standby Time Standard Machine
Output Capacity Medium Type
Brand Richwin/OEM/ODM/Neutral
Transport Package Carton/Wooden
Origin Shenzhen, China
Phase Three Phase
Protection Overvoltage
Classification Lighting/Power
Standby UPS Sine Wave Output UPS
Equipment Mode Centralized Model
Trademark Richwin/OEM/ODM/Neutral
Specification 282× 145× 220mm5× 220mm220mm5× 220mm
HS Code 8504402000
10kVA~20kVA High Frequency Pure Sine Wave Three Phase Online UPS
RH31(10~20K) SERIES
This UPS is the perfect protection partners for computer, Workstations and POS system. Widely used in municipal, bank, postal coupons, communication transportation ,radio and television, and power Public hospital, industrial control, defense, etc, Computer room, data center, and the server for electric power Environmental requirements of network equipment, strict communication and information.

Function Features

True double-conversion online UPS
DSP technology guarantees high performance
Output power factor0.8
Wide Input voltage range( 3-phase 1 90-520 VAC )
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
ECO mode for energy saving
Generator compatible
Programmable power management outlets
Emergency power off function(EPO)
Charger capacity expansion to 8A for long-run models
3-stage extendable charging design for optimized battery performance
SNMP+USB+RS-232 multiple communications
Maintenance bypass available
Optional N+X parallel redundancy
Specification
MODEL RH31-10KS RH31-15KS RH31-20KS
CAPACITY 10000VA/ 8000W 15000VA/ 12000W 20000VA / 16000W
INPUT
Phase 3PH 4W+G
Input VoltageRange 190-520 VAC (3-phase)@ 50% load
305-520 VAC (3-Phrase)@100% load
Frequency Range 46-54Hz or 56-64Hz
Power Factor >=0.99@ Nominal voltage(100% load)
OUTPUT
Phase 1PH 2W+G
Output Voltage 208/220/230/240VAC
Voltage Regulation ±±plusmn;±1%
Frequency Range(Synchronized Range) 46-54 Hz or 56~64 Hz
Frequency Range(Batt. Mode) 50 Hz±±plusmn;±0.1Hz or 60Hz±±plusmn;±0.1 Hz
Current Crest Ratio 3 : 1
Harmonic Distortion <=2% THD(Linear Load), <=5% THD(Non-linear Load)
Transfer
Time
AC to DC Zero
Inverter to Bypass Zero
Waveform(Batt. Mode) Pure Sine wave
EFFICIENCY
To AC Mode 91% 91% 91%
ToBatteryMode 91% 91% 91%
BATTERY
Long-run
Model
Battery Numbers Depending on the capacity of external batteries
Charging Current(max.) 4A 4A
Charging Voltage 218.4VDC±±plusmn;±1%
INDICATORS
LCD UPS status, Load level,Batterylevel, Input / Output voltage, Discharge timer, and Fault indicators
PHYSICAL
Long-run
Model
Dimension ,D××times;×W××times;×H(mm) 442×19imes;19imes;190×318mes;318mes;318
Net Weight(kgs) 28 40 40
ENVIRONMENT
Humidity 20-90% RH@ 0-40ºCordm;Cordm;C(Non-condensing)
Noise Level Less than 50dBA@ 1 Meter
MANAGMENT
Smart RS-232/USB Support Windows@2000/2003/XP/Vista/2008, Windows@7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
*Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.