Offline UPS for Compute 1000va With AVR and Standby
1: Offline UPS with AVR Function and with Short Circuit protection
2: LCD Display offline UPS
3: Standby UPS 1000W with AVR
Details:
Offline UPS, LCD UPS - Offline LCD UPS
1: Offline UPS with AVR Function and with Short Circuit protection
2: LCD Display offline UPS
3: Offline UPS with USB/RS232/RJ11/RJ45 Ports
4: UPS Single Phase, 110V/120V or 220/230/240VAC In/Out
Offline LCD UPS Optional function
Line Surge Protection: RJ11/RJ12/RJ45, Communication Interface: RS232
Control mode: CPU controller
Function & Characteristic:stic:stic:
AVR, Overload and short circuit protection
Low battery alarm, LED status display
UPS Auto on when AC back, Night charging(optional)
Built-in Sealed lead acid batteries inside
USB Port is optional
Standby offline Mode
CE certificate, low fault rate and 1 year warranty
Quality is competitive with APC, Santak and Eaton UPS.
| MODEL | N400 | N500 | N650 | N800 | N1000 | N1200 | N1500 |
| Nominal Capacity | 400VA | 500VA | 650VA | 800VA | 1000VA | 1200VA | 1500VA |
| Input | Voltage Range | 145~280VAC/ 80VAC-150VAC |
| Frequency | 50/60Hz |
| Output | Voltage Range | 220VAC/120VAC ± 10%smn; 10%smn; 10% |
| Frequency | 50Hz/60Hz ± 5%usmn; 5%usmn; 5% |
| Output Waveform | Sine Wave (AC Mode), Square Wave (Battery mode) |
| Transfer time | < 8ms 8ms |
| Battery | Type | Sealed free maintenance lead acid battery |
| Capacity | 12V, 4AH *1PCS | 12V, 7AH *1PCS | 12V, 7AH *1PCS | 12V, 9AH *1PCS | 12V, 7AH *2PCS | 12V, 9AH *2PCS | 12V, 9AH *2PCS |
| Recharge Time | 8 hrs to 90% of capacity full load discharge |
| Protection | Auto protect |
| Back-up time(at a PC load with 15' monitor )itor ) | 10 minutes | 18 minutes | 18 minutes | 22 minutes | 30 minutes | 35 minutes | 35 minutes |
| Function | Auto voltage output on AC mode, Auto shutoff if short circuit or overload |
| DB-9 port, communication software | Optional RS232, RJ11, RJ45, USB |
| Protection | AC mode | Fuse |
| Short circuit | AC | Fuse |
| Invert mode | Auto protect |
| Alarm | Alarm | Battery discharge | Alarm beeps every four seconds |
| Low battery voltage | Alarm beeps every second |
| Overload | Alarm beeps continuously |
| Indicator light | Auto adjust | Green lighting: AC mode |
| Battery Discharge | Red lighting: Battery mode |
| Environment | Operating temperature | 0 ° C ~40 ° C0 ° Cg; C0 ° C |
| Operating Humidity | 0-90% non-condensing |
| Noise | < 35dB ( 1 meter distance )ce ) |
| UPS Dimension ( L× W× H ) mmtimes; H ) mmtimes; H ) mm | 275*90*138 | 335*103*152 | 345*122*190 |
| Net weight (N. W) | 4.5KG | 6.5KG | 6.8KG | 7.5KG | 11KG | 12KG | 13KG |
| Gross weight (G. W) | 4.7KG | 6.7KG | 7KG | 7.7KG | 11.3KG | 12.3KG | 13.3KG |