LED Offline UPS-Computer Power System UPS-400VA-1500VAUPS
Product Features
IP/OP: 110/220VAC 50/60Hz
IP/OP: 110/220VAC 50/60Hz
KEY FEATURES
Optional function
Line Surge Protection: RJ11/RJ12/RJ45, Communication Interface: RS232
Function & Characteristic:stic:stic:
AVR, Overload and short circuit protection
Low battery alarm, LED status display
UPS Auto on when AC back, Night charging(optional)
APPLICATION
Home, computer, printer, POS, computer peripherals
Product performance
TECHNICAL SPECIFICATION
MODEL
N400
N500
N650
N800
N1000
N1200
N1500
Nominal Voltage
400VA/240W
500VA/300W
650VA/390W
800VA/480W
1000VA/600W
1200VA/720W
1500VA/900W
Input
Voltage Range
145~280VAC
Frequency
50/60Hz
Output
Voltage Range
220VAC ± 10%smn; 10%smn; 10%
Frequency
50Hz ± 5%usmn; 5%usmn; 5%
Output Waveform
Square Wave
Transfer time
< 10ms10ms
Battery
Type
Sealed free maintenance lead acid battery
Capacity
12V, 4AH *1PCS
12V, 7AH *1PCS
12V, 7AH *1PCS
12V, 9AH *1PCS
12V, 7AH *2PCS
12V, 9AH *2PCS
12V, 9AH *2PCS
Recharge Time
8 hrs to 90% of capacity full load discharge
Protection
Auto protect
Back-up time( Full load )
3~5 min
5~7 min
7~10 min
6~8 min
5~7 min
8~10 min
10-12min
Function
Auto voltage output on AC mode, Auto shutoff if short circuit or overload
dB-9 port, communication software
Optional RS232, RJ11, RJ45, USB
Protection
AC mode
Fuse
Short circuit
AC
Fuse
Invert mode
Auto protect
Alarm
Alarm
Battery discharge
Alarm beeps every four seconds
Low battery voltage
Alarm beeps every second
Overload
Alarm beeps continuously
Indicator light
Auto adjust
Green lighting: AC mode
Battery Discharge
Red lighting: Battery mode
Environment
Operating temperature
0C~40C
Operating Humidity
0-90% non-condensing
Noise
<35dB (1 meter distance)nce)
UPS Dimension (L× W× H) mmW× H) mmH) mmW× H) mm
325*90*150
335*100*150
345*125*190
Net weight (N. W)
4.5KG
6.5KG
6.8KG
7.5KG
11KG
12KG
13KG
Gross weight (G. W)
4.7KG
6.7KG
7KG
7.7KG
11.3KG
12.3KG
13.3KG
| Nominal Voltage | 400VA/240W | 500VA/300W | 650VA/390W | 800VA/480W | 1000VA/600W | 1200VA/720W | 1500VA/900W |
| Input | Voltage Range | 145~280VAC |
| Frequency | 50/60Hz |
| Output | Voltage Range | 220VAC ±10%usmn;10%usmn;10% |
| Frequency | 50Hz ±5%lusmn;5%lusmn;5% |
| Output Waveform | | | Square Wave | | |
| Transfer time | < 10ms10ms |
| Battery | Type | Sealed free maintenance lead acid battery |
| Capacity | 12V,4AH *1PCS | 12V,7AH *1PCS | 12V,7AH *1PCS | 12V,9AH *1PCS | 12V,7AH *2PCS | 12V,9AH *2PCS | 12V,9AH *2PCS |
| Recharge Time | 8 hrs to 90% of capacity full load discharge |
| Protection | Auto protect |
| Back-up time( Full load ) | 3~5 min | 5~7 min | 7~10 min | 6~8 min | 5~7 min | 8~10 min | 10-12min |
| Function | Auto voltage output on AC mode, Auto shutoff if short circuit or overload |
| DB-9 port,communication software | Optional RS232, RJ11, RJ45, USB |
| Protection | AC mode | Fuse |
| Short circuit | AC | Fuse |
| Invert mode | Auto protect |
| Alarm | Alarm | Battery discharge | Alarm beeps every four seconds |
| Low battery voltage | Alarm beeps every second |
| Overload | Alarm beeps continuously |
| Indicator light | Auto adjust | Green lighting: AC mode |
| Battery Discharge | Red lighting: Battery mode |
| Environment | Operating temperature | 0C~40C |
| Operating Humidity | 0-90% non-condensing |
| Noise | <35dB (1 meter distance)nce) |
| UPS Dimension (L×W×H) mmW×H) mm;H) mmW×H) mm | 325*90*150 | 335*100*150 | 345*125*190 |
| Net weight (N.W) | 4.5KG | 6.5KG | 6.8KG | 7.5KG | 11KG | 12KG | 13KG |
| Gross weight (G.W) | 4.7KG | 6.7KG | 7KG | 7.7KG | 11.3KG | 12.3KG | 13.3KG |