Emergency Computer UPS with AVR 400VA-1500VA Key Features 0. Used in protection of computers and SMEs etc.
1. 400va to 1500va, High rate, low noise as a good standby for about 8-35mins
2. AC mode sine wave(sync with line), battery mode:square wave
3. 135 to 295vac or 65 to 150vac input, 220/230vac or 110/120vac output
4. Internal battery type is sealed free maintenance lead acid battery
5. Battery capacity: 12v, 4ah to 9ah
6. Recharge time is 8 hrs to 90% of capacity full load discharge
7. off mode charging
8. Modem/line surge protection:RJ11/RJ12/RJ45
9. Overload/ Over charge/Short-circuit and overcurrent protection.
10. Smart RS-232 or USB communication port with free download software from Internet
11. Low battery alarm,LED display.
12. Net weight is from 4.0kg to 11.5kg
Specifacation | MODEL | N400 | N500 | N650 | N800 | N1000 | N1200 | N1500 |
| Nominal Voltage | 400VA/240W | 500VA/300W | 650VA/390W | 800VA/480W | 1000VA/600W | 1200VA/720W | 1500VA/900W |
| Input | Voltage Range | 145~280VAC |
| Frequency | 50/60Hz |
| Output | Voltage Range | 220VAC ±10%usmn;10%usmn;10% |
| Frequency | 50Hz ±5%lusmn;5%lusmn;5% |
| Output Waveform | | | Square Wave | | |
| Transfer time | < 10ms10ms |
| Battery | Type | Sealed free maintenance lead acid battery |
| Capacity | 12V,4AH *1PCS | 12V,7AH *1PCS | 12V,7AH *1PCS | 12V,9AH *1PCS | 12V,7AH *2PCS | 12V,9AH *2PCS | 12V,9AH *2PCS |
| Recharge Time | 8 hrs to 90% of capacity full load discharge |
| Protection | Auto protect |
| Back-up time( Full load ) | 3~5 min | 5~7 min | 7~10 min | 6~8 min | 5~7 min | 8~10 min | 10-12min |
| Function | Auto voltage output on AC mode, Auto shutoff if short circuit or overload |
| DB-9 port,communication software | Optional RS232, RJ11, RJ45, USB |
| Protection | AC mode | Fuse |
| Short circuit | AC | Fuse |
| Invert mode | Auto protect |
| Alarm | Alarm | Battery discharge | Alarm beeps every four seconds |
| Low battery voltage | Alarm beeps every second |
| Overload | Alarm beeps continuously |
| Indicator light | Auto adjust | Green lighting: AC mode |
| Battery Discharge | Red lighting: Battery mode |
| Environment | Operating temperature | 0C~40C |
| Operating Humidity | 0-90% non-condensing |
| Noise | <35dB (1 meter distance)nce) |
| UPS Dimension (L×W×H) mmW×H) mm;H) mmW×H) mm | 325*90*150 | 335*100*150 | 345*125*190 |
| Net weight (N.W) | 4.5KG | 6.5KG | 6.8KG | 7.5KG | 11KG | 12KG | 13KG |
| Gross weight (G.W) | 4.7KG | 6.7KG | 7KG | 7.7KG | 11.3KG | 12.3KG | 13.3KG |
Photos