Model NO. RV500-1000
Type Line Interactive
Application Home/Office
Standby Time Standard Machine
Output Capacity Medium Type
Brand Richwin/OEM/ODM/Neutral
Capacity 500va-6000va
Display LED/LCD Optional
Voltage Range 81-145 VAC / 145-275VAC
Transport Package Carton/Wooden
Origin Shenzhen, China
Phase Single Phase
Protection Overvoltage
Classification Lighting/Power
Standby UPS Sine Wave Output UPS
Equipment Mode Centralized Model
Outlets Universal
Certificate Ce, IEC,LVD
Voltage 110/120/220/230(± 25%) VAC 25%) VAC25%) VAC
Trademark Richwin/OEM/ODM/Neutral
Specification upon the model
HS Code 8504402000
0.5-6KVA Pure Sine Wave Backup UPS
RV500-1000
Charecteristics
1 . Accurate pure sine wave output; strong capacity of different load
2. Smart RS232 communication port (only for model B)
3. Advanced performance due to the CPU control
4. Wide range with power input and accurate output AVR
5. Perfect protection for overload, short circuit, over-voltage, low-voltage and over-heating etc
6. LED/LCD display (optional)
7. UPS start automatically when the main power recover (optional)
8. Intelligent battery management

Specification
MODEL RV500 RV800 RV1000 RV1500 RV2000 RV3000 RV5000 RV6000
CAPACITY 500VA/300W 800VA/480W 1KVA /700W 1500VA/1050W 2KVA /1400W 3KVA /2100W 5KVA /3000W 6KVA /3500W
INPUT
Voltage 110/120/220/230(± 25%) VAC25%) VAC25%) VAC
Voltage Range 81-145 VAC / 145-275VAC
Frequency Range 60/50 ± 1% Hz (auto sensing)sensing)sensing) 40-68Hz
OUTPUT
AC Voltage Regulation ±10%usmn;10%usmn;10%
Frequency Range 60 Hz or 50 Hz ±1 Hzsmn;1 Hzsmn;1 Hz
Transfer Time Typical 2-6 ms, 10ms max.
Waveform (Batt. Mode) Pure sine Wave
BATTERY
Battery Type & Numberumberumber 12V/7AHx1 12V/9AHx1 12 V/7AH x 2 12 V/9AH x 2 12 V/17AH x 2 12 V/17AH x 2 12 V/17 AH x 4 DC48V
backup time@80% load 20 minutes 25 minutes 13 mins 11 mins 16 mins 10 mins 14 mins /
Recharge Current ( Standard model) Standard model:max 3A Standard model:max 5A
Recharge Current (S model) Long back up S model:max 20-25A
INDICATORS
LCD/LED Optional
PROTECTION
Overload Shut down if overload exceeds 120% /normal value for 30 seconds
Short circuit Cut off immediately or input circuit breaker protection
ALARM
Low Battery Beeping every second
Overload Audible alarm
Fault Continuously beeping
PHYSICAL
Product size, D X W X H (mm) 330 x 100 x 140 380 x 140 x 182 450 x 190 x 350
Carton size, D X W X H (mm) 465 x 215 x 285 595x 325 x 473
M Net Weight (kgs) 5 8 15.2/11 15.9/12.8 37.5/27.7 37.5/27.7 54.2/29.6 29.6
OPERATING ENVIRONMENT
Humidity 0-90 % RH @ 0- 40°C (non-condensing)sing)sing)
Noise Level Less than 40dB Less than 60dB
MANAGEMENT