MPPT Solar Charge Controller 40A 60A
Solar Controller - MPPT Solar Charge Controller 12/24V
Solar Controller Advantages:
1: Solar Controller/Regulator with MPPT Technology
2: Controller/Regulator DC 12V and 24V auto detect
3: Three stage charge system for controller
4: Overcharge protection during controller work
Solar Controller - MPPT Solar Charge Controller/regulator 12/24V
Key Features:
1: Model: MPPT Solar charge controller 12V/24V 40A, SL-40A
2: High converting efficiency higher than 97% for minimizing energy loss
3: Build-in MPPT tracker for opeimizing the power transformation
4: Reversed current protection for preventing equipment damage
5: Automatic battery temperature compensation for long term reliability
6: Capable of selecting different charging mode for various type of batteries
7: Capable of connecting additional DC load for wider applications
8: Three stage charge control system(bulk, absorption, and float mode) with temperature compensation
8: LED indicators display charge status in real time
9: Pulse width modulation(PWM) topology combined with a multi-stage charge control algorithm leads to superior charging and enhanced battery performance.
| MPPT solar charger controller | SL-40A/60A |
| Rated Voltage | 12/24/48Vdc auto-detection |
| Rated charge current (include load current) | 40Amp/60Amp |
| Load current | 15Amp |
| Input voltage range | 15-55Vdc |
| Max. PV open circuit array voltage | 55Vdc |
| Overload protection (DC load) | 2.0 * Inom﹥5st;5s |
| 1.5 * Inom ﹥20s;20s |
| 1.25 * Inom temperature controlled |
| Typical idle consumption | At idle < 10mA10mA |
| Bulk charge | 14.6Vdc (default) | 29.2Vdc (default) |
| Floating charge | 13.4Vdc (default) | 26.8Vdc (default) |
| Equalization charge | 14.0Vdc (default) | 28.0Vdc (default) |
| Over charge disconnection | 14.8Vdc | 29.6Vdc |
| Over charge recovery | 14Vdc | 28Vdc |
| Over discharge disconnection | 10.8Vdc (default) | 21.6Vdc (default) |
| Over discharge reconnection | 12.3Vdc | 24.6Vdc |
| Temperature compensation | -13.2mV/ | -26.4mV/ |
| Lead acid battery settings | Adjustable |
| NiCad battery settings | Adjustable |
| Load control mode | 1. Low Voltage Reconnect (LVR): Automatic |
| 2. Low Voltage Disconnect (LVD): Automatic |
| 3. Reconnection: warning flash before disconnect and reconnection |
| Low voltage reconnect | 12.0-14.0Vdc | 24.0-28.0Vdc |
| Low voltage disconnect | 10.5-12.5Vdc | 21.0-25.0Vdc |
| Ambient temperature | 0-40 (full load) 40 - 60 (de-rating) |
| Altitude | Operating 5000 m, Non-Operating 16000 m |
| Protection class | IP21 |
| Cooling | natural cooling |
| Terminal size (fine/single wire) | #8 AWG |
| Dimension(L*W*H) | 192*140*66mm |