| Model | PC16-4515F | PC16-6015F |
| Default Battery system Voltage | 24v/48vdc(adjustable) |
| Charge Input |
| PV Open Circuit Voltage range | Operational max=145VDC temperature correct VOC |
| Max PV input power(24v) | 1200W | 1600W |
| Max PV input power(48v) | 2400W | 3200W |
| Battery voltage |
| Nominal Voltage | 24V / 48V |
| Absorption Voltage | 27.0V / 54.0V |
| Refloat Voltage | 27.4V / 54.8V |
| Float Voltage | 28.6V / 57.2V |
| Low voltage protection point | 21.0V / 42.0V |
| DC Output |
| Output Voltage | 22.0-28.6V / 44V-57.2V |
| Rated Current | 45A continuous @40 ambient | 60A continuous @40 ambient |
| Warning for low voltage | 23.0V / 46.0V |
| Cut off for low voltage | 21.6V / 43.0V |
| Low voltage recovery | 26.0V / 46.0V |
| Display |
| LED indication | Systematic operation, LV indication, LV protection, over charge protection, loads protection, short circuit protection |
| LCD display(optional) | Charge voltage, charge current, voltage of storage battery, capacity of storage battery, output current |
| Alarm Protections | 1.PV array short circuit protection, PV reverse polarity protection 2.Battery reverse polarity protection , Over charging protection 3.Output short circuit protection 4.Low voltage protection for storage battery |
| General specification |
| Protection Level | In compliance with regulations of DIN EN60529 and standards of IP22 |
| Charge mode | PWM ,constant current_constant voltage, function of automatic protection for storage battery |
| Radiating mode | Fan cooling |
| Working mode | General controller |
| Efficiency | ≥98%;98%;98% |
| Self -consumption | < 10mA10mA | < 15mA15mA |
| Environment |
| Environmental temperature | -10 --55 |
| Ambient humidity | 0--90%,No condensation |
| Altitude | ≤4500m500m500m |
| Dimension |
| Unit size D*W*H(mm)/G.W(kg) | 257.1*167.6*82.9mm/3kg |
| Package size D*W*H(mm)/G.W(kg) | 390*365*365mm(6pcs/carton)/19kg |