Outdoor UPS 500va~3000va (pure sine wave line interactive)

Outdoor UPS 500va~3000va (pure sine wave line interactive)

bargain

add to cart
Model NO. 500VA, 100VA, 2000VA, 3000VA
Type Pure Sine Wave Interactive Outdoor UPS
Application Communication, Networking, Traffic Control
Transport Package Carton Box
HS Code 85044020
Phase Single Phase
Protection Overvoltage
Trademark EAST
Origin China
Pure Sine Wave Line Interactive 500-3000VA outdoor UPS is specially designed for outdoor communication equipment, networking equipment, traffice control system and other application of city corner, contryside, or mountainous area. It is equipped with high temperature/frost/corrosion/water resistance and dust prevention. With feature such as wide range of input voltage and freqeuncy, anti-thunder, remote control and remote detction ect, it guarantee stable power supply and become an ideal helpmate for these important outdoor devices.
Features:
Strong environmental adaptability
High reliability, energy saving, environmental protection
Wide adaptability to power grid
Unattended and intelligent monitoring (option)
Inverter isolation & pure sine wave technologynologyology
Online UPS protection function
Intelligent no-load shut-off (option)
Auto restart when mains power is restored
Technical Data:
MODEL 500VA 1000VA 2000VA 3000VA
Power 300W 600W 1200W 1800W
DISPLAY
Panel indicator LED / LCD (customized)
MAINS STATES
Load PC, banking system, ATM, medical system
Input voltage range 100V/110V/120V/220V/230V/240V±25% / -35%-25% (customized)tomized)tomized)
Input frequency range 45-65 Hz (over-frequency automatically transfer to inverter power)
Stable output voltage range 100V/110V/120V/220V/230V/240V±10%usmn;10%usmn;10%
Input P.F.(AC/DC) 98%
Efficiency Mains mode ≥ 96% 96% 96%
Mains overload 110% in 60s transfer to bypass power, 120% in 30s transfer to bypass power, automatically recover when decrease the load
Short circuit Input fuse
INVERTER STATES
Inverter output voltage 100V/110V/120V/220V/230V/240V± 5% battery≥11Vdc)y≥11Vdc)dc)y≥11Vdc)
Output frequency 50 Hz / 60Hz ±1% frequency adaptiveadaptiveadaptive
Output power factor ≥0.6;0.6;0.6
Waveform distortion Linear load≤ 5%; 5%; 5%
Transfer time 5ms typical Max.8 ms
Efficiency Inverter mode≥80%;80%;80%
Inverter overload 110% in 60s shut down, 120% in 5s shut down
No-load shut-off (option) load< 5% 1MIN the system automatically shut downdown
Short circuit the system automatically shut down
ALARM
Mains abnormal 1/4S, automatically mute in 40s
Low battery 1/ 0.2s
Overload 1/ 1S
BATTERIES
DC voltage 24 Vdc 48Vdc
Inner battery space 2×38Ah / 2×120Ah2×120Ah;120Ah2×120Ah 4×38Ahes;38Ahes;38Ah 4×120Ahs;120Ahs;120Ah
Charge current 12A Max
Communication interface (option) Dry contacts / RS232 / USB / SNMP
OTHERS
Installing Floor-type or wall-hang
Surge protection Class C
Safety GB4943-2001,IEC IEC62040-2:2006
EMC EA50091-2;IEC62040-1:2006;EA61000-3-2:2006; EA61000-3-3:2008
Protection grade IP55
Environmental temperature 0ºC ~ 50ºC (-30ºC Option )ºC Option )ion )ºC Option )
Environmental humidity 10% ~ 95%( no cooling)
Noise 50dB
Weight (kg) 17.5/36.7 36.7 60.7
Dimensions (mm) WxDxH 430×245×550 / 470×245×900/ 470×245×90045×900/ 470×245×900 470×245×900245×900es;900245×900 800×560×110060×1100s;110060×1100
Packing dimensions (mm) WxDxH 500×330×620 / 540×330×980/ 540×330×98030×980/ 540×330×980 540×330×980330×980es;980330×980 948×648×114248×1142s;114248×1142