Model NO. EH5100
Type On-line
Application Communication
Standby Time Long-acting Machine
Output Capacity Large Type
Waveform Pure Sine Wave
Trademark MUST or OEM
Specification CE ISO9001
HS Code 8504402000
Phase Single Phase
Protection Most Power Problems
Classification Uninterrupted Power Supplies
Standby UPS Sine Wave Output UPS
Brand Must
Transfer Time 0 Transfter Time
Transport Package Cartons Packing, 700PCS/20′ Containerontainerntainer
Origin Shenzhen, China
Sine wave output, Zero conversion time
Input zero frontline detection function, Bypass output
DC starting, Bypass protection
Automatic startup function, Long-term type power design
Strong ability to recharge long-term acting machine
Shelf-check function, Powerful anti-jamming
Can match generator
Support inductive load too
Winpower2000 monitoring software free downloads
Provide intelligent slot, Provide standard battery pack


Product Series

EH5110 Rack mount online ups

Model

HR1K/HR1KS

HR2K/HR2KS

HR3K/HR3KS

HR6K/HR6KS

Rated Power

VA/W

1KVA / 0.7KW

2KVA / 1.4KW

3KVA / 2.1KW

6KVA/4.2KW

Input

Nominal Voltage

220VAC

Voltage Range

115 ~ 300VAC

176 ~ 276VAC

Frequency Range

46 ~ 54Hz(default), user adjustable within 40~60Hz

46 ~ 54Hz

Power Factor

0.97

0.98

Connection

IEC320-10A inlet

IEC320-16A inlet

Terminal Block

Output

Voltage

220VAC ± 2%usmn; 2%usmn; 2%

220VAC ± 1%usmn; 1%usmn; 1%

Frequency

46~54Hz or 50Hz ± 0.2Hz (Line mode)ne mode)ne mode)
50Hz ± 0.2Hz ( Battery mode)ry mode)ry mode)

46~54Hz (Line mode)
50Hz ± 0.05Hz ( Battery mode)ry mode)ry mode)

Waveform

Sine Wave

Overload Capability

108%~150% for 30 sec., ³150% for 300 ms300 ms300 ms

105%~130% for 10 min., ³130% for 1 min.1 min.1 min.

Current Crest Ratio

3:1

Bypass

Automatic Transfer

on overload and UPS failure

Before UPS Power-on

Default 'NO', user adjustable to 'YES'le to "YES"t;YES"

Yes

Voltage Range

80~264VAC (Default), user adjustable within 80~286VAC

176 ~ 261VAC

Output Connections

IEC320 -10A * 4

IEC320-10A * 4

IEC320-10A and
Terminal Block

IEC320-10A * 4 and Terminal Block

Transfer Time

0 ms; less than 4 ms from inverter to bypass and vice versa

Zero

LED indicators

Status

Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault

Audible Alarm

Bypass, On battery mode, Battery low, Overload, Fault

Communications

RS-232 Serial Interface

Intelligent Slot;
OPTIONS: WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC)

Network Surge Protection

RJ45 I/O port available for network or Fax/Modem

Environmental

Operating Temperature

0 ~ 40°Cdeg;Cdeg;C

Operating Humidity

20 ~ 90% non-condensing

Main Unit

Net Weight (Kg)

15.3

10.3

11.2

18.3

Dimensions (W x D x H) mm

482.6 x 450 x 88 (2U)

482.6 x 600 x 130 (3U)

Battery Pack

Type

Internal Batteries

External Battery Pack

Nominal DC Voltage

36VDC

96VDC

240VDC

Backup Time (Full load)

5 min

9 min
(with 1 BP)

5 min
(with 1 BP)

7 min
(with 1 BP)

Net Weight (Kg)

--

25.3

58.2

Dimensions (W x D x H) mm

--

482.6 x 450 x 88 (2U)

482.6 x 600 x 130 (3U)