Very Popular High Frequency Online UPS 3 Phase in 1 Phase out 15kVA UPS

Very Popular High Frequency Online UPS 3 Phase in 1 Phase out 15kVA UPS

560 USD

add to cart
Model NO. EH50000
Type On-line
Application Communication
Standby Time Long-acting Machine
Output Capacity Large Type
Brand Must or OEM
Frequency 50/60Hz
Charge Current Max 4.5 MP
Power Factor 0.8
Specification CE certificates
HS Code 8504409990
Phase Three Phase
Protection Most Power Problems
Classification Lighting/Power
Standby UPS Sine Wave Output UPS
Equipment Mode Decentralized
Wave Form Pure Sine Wave
Capacity 10k-20kVA
Input Voltage 207-476VAC
Trademark MUST or OEM
Origin China
Main Features:
Parallel Units with a Single Output of up to 80kVA
True N+1 Redundancy
DSP Double-Conversion On-line Sinewave Design
Input Power Factor Correction
LCD Display with Advanced Monitoring for Easy UPS Management
Programmable 50/60Hz Frequency Conversion
Wide Input Voltage Window
Precision Output Voltage Regulation
Superior Brownout, Surge & Transient Protectionctionction
Optional Extended Battery Banks & Chargersrgersrgers
RS-232C, RJ45 & Optional SNMP/HTTP AgentAgentAgent
WINPOWER® UPS Monitoring & Management Software Software Software
Model EH5000-3H10KS EH5000-3H15KS EH5000-3H20KS
Capacity 10kVA/7KW 15KVA/10.5KW 20KVA/14KW
INPUT
Phase 3 phase with ground
Frequency Range 46~54HZ
Power Factor >=0.95
Acceptable Voltage 60~138 Vac
Voltage Range Line Low Transfer 304VAC +/- 3VAC
Line Low Comeback 322VAC +/- 3VAC
Line High Transfer 478VAC +/- 3VAC
Line High Comeback 361VAC +/- 3VAC
OUTPUT
Phase Single
Voltage 220VAC/230VAC/240VAC
Voltage Regulation ± 1%usmn; 1%usmn; 1%
Frequency ( Synchronized Range) 46~54Hz
Frequency( Battery Mode) 50 ± 0.05 Hz 0.05 Hz 0.05 Hz
Current Crest Ratio 3:1
Harmonic Distortion <= 2% THD ( Linear Load) /<= 6% THD ( Non-Linear Load)r Load)
Output Waveform Pure Sinewave
EFFICIENCY
To AC Mode 88%
To Battery Mode
BATTERY
Battery Type Lead acid battery
Numbers of Batteries 20 PCS
Backup Time (Full Load) Depending on the capacity of external batteries.
Recharge Time 10 hours for 80% capacity
DC Voltage 240V
Charging Current (Max.) 4.5A
Charging Voltage 274Vdc ± 1%Vsmn; 1%Vsmn; 1%V
TRANSFER TIME
AC to DC Zero
Inverter to Bypass Zero
LED-INDICATOR
Status Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault
AUDIBLE ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously Sounding
DIMENSION
UPS Case D x W x H (mm) 248*500*616
WEIGHT
Net Weight(kgs) 30 38 38
ENVIRONMENT
Operating Temperature 0~40 ° C , 20~90% relative humidity (non-condensing)sing)sing)
Noise Level <60dB @ 1 Metereter
INTERFACE
Smart RS-232 Windows 98/NT/2000/XP/2003/ME, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC
SNMP (option) Power management from SNMP manager and web browser