Home UPS Line Interactive Design 500-1500va

Home UPS Line Interactive Design 500-1500va

35 USD

add to cart
Model NO. 500va-1500va(EW2000)
Type Line Interactive
Application Communication
Standby Time Standard Machine
Output Capacity Large Type
Brand Must
AC Brownout Solution 3-Step AC Voltage Regulation,Wide Input AC Range
Home UPS AVR Line Interactive Design 500va to 1500va
Transport Package Carton Gift Boxes
Origin Shenzhen, China
Phase Single Phase
Protection Input Surge Voltage,Over(Load,Temperature)...
Classification Lighting/Power
Standby UPS Sine Wave Output UPS
Equipment Mode Centralized Model
AC Blackout Solution PWM Tech Inverter and Min 7ah Internal Battery
Communication and Power Management USB + Winpower Shut-Down Software
Trademark Must
Specification CE
HS Code 8504402000
Home ups line interactive design 500-1500va with usb communication interface
Feature:
1. Micro-processor intelligent control: Reliability;
2. PWM tech dc-ac inverter functions when ac blackout, provides some time backup from internal battery;
3. PWM inverter and internal battery manages ac-blackout problem;
4. Full ac voltage regulation from 3-step boost/buck avr allow ups work stably in a wide input voltage range
(145-290Vac), avoid battery discharge better, solve ac-brownout problem better;
5. Intelligent battery charge control(3-stage charge), and over-discharge protection/battery low;
6. Convenient usb communication port for easy power management, together with winpower software.
MODEL EA1000-500 EA1000-650 EA1000-800 EA1000-1000
CAPACITY 500VA/300W 650VA/390W 800VA/480W 1000VA/600W
INPUT
Voltage Nominal Voltage 110/120 VAC or 220/230/240 VAC
Acceptable Voltage Range 90-145 VAC/150-290 VAC
Frequency Range 50 /60 Hz
OUTPUT
AC Voltage Regulation (Batt. Mode) ±10%usmn;10%usmn;10%
Frequency Range (Batt. Mode) 50 Hz or 60 Hz
Transfer Time (Typical) 2-6 ms
Waveform (Batt. Mode) Modified Sinewave
BATTERY
Battery Type & Numbersmbersmbers 12 V 7 Ah x 1 12 V 7 Ah x 1 12 V 9 Ah x 1 12 V 7 Ah x 2
Back up Time(at a PC load 8 minuters 10 minuters 20 minuters 20 minuters
Typical Recharge Time 10 hours to 90% after complete discharge
INDICATORS
AC Mode Green LED lighting
Battery Mode Green LED flashing every 4 seconds
Low Battery at Battery Mode Green LED flashing every second
Fault Red LED lighting
Battery Fault at AC modes Green LED flashing three times every 2 seconds
Battery Week at AC modes Red LED flashing every 2 seconds for 30 seconds
Overload Red LED flashing every twice every second
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Fault Continuously sounding
PHYSICAL
Dimension, D X W X H (mm) 295*95*140
Net Weight (kgs) 5.5 6.2 6.8 10.5
ENVIRONMENT
Humidity 0 to 90% Relative Humidity(Non-condensing)
Operating Temperature 0°Cto 40°C 40°Ceg;C 40°C