Must Eh5110 Best Quality Rack Mounted Online UPS

Must Eh5110 Best Quality Rack Mounted Online UPS

99 USD

add to cart
Model NO. EH5110
Type On-line
Application Communication
Standby Time Standard Machine
Output Capacity Medium Type
Brand Must/OEM
AC-Mode to Battery-Mode Zero Transfer Time
Battery Charge Control Fast Charge at Constant Voltage
Weight 8-41kg, Depends on Different Models
Power 1kVA, 2kVA, 3kVA
Communication Interface RS232
Specification CE ISO9001 certificates
HS Code 8504402000
Phase Single Phase
Protection Overvoltage
Classification Lighting/Power
Standby UPS Sine Wave Output UPS
Equipment Mode Decentralized
Item Rack Mounted Online UPS
Output Voltage 110-300V or 120-276V, 208/220/230/240VAC
Wave Form Pure Sine Wave
Color Black
Wide Frequency 40 - 70Hz
Trademark MUST or OEM
Origin China
Must EH5110 best quality Rack Mounted Online Ups
1, wide input 160-300V
2, O transfer time
3, 1000va to 20kVA
4, LED or LCD display
5, tower or rack outlook
1. Smart RS232
2. ZERO transfer time
3. Intelligent slot available
4. Maintenance free battery
5. The best After-Sales Service
Model EH1KR EH1KRS EH2KR EH2KRS EH3KR EH3KRS EH6KR EH6KRS
CAPACITY 1000VA/700W 2000VA/1400W 3000VA/2100W 6000VA/4200W
INPUT
Phase Single Phase with Ground
Frequency Range 50Hz:46~54Hz
Power Factor >=0.97 >=0.98
Voltage Range Base on load percentage (100%-80% / 80%-70% / 70%-60% / 60%-0%)
Line Low Transfer 160VAC/140VAC/120VAC/110VAC± 5VACmn; 5VACmn; 5VAC 176 ±3% VACn;3% VACn;3% VAC
Line Low Comeback 175VAC ± 5VACmn; 5VACmn; 5VAC 185 ± 3% VAC; 3% VAC; 3% VAC
Line High Transfer 300VAC± 5VACmn; 5VACmn; 5VAC 276 ± 3% VAC; 3% VAC; 3% VAC
Line High Comeback 285VAC± 5VACmn; 5VACmn; 5VAC 266 ± 3% VAC; 3% VAC; 3% VAC
OUTPUT
Phase Single
Voltage 220VAC/230VAC/240VAC
Voltage Regulation ± 2%usmn; 2%usmn; 2% ± 1%usmn; 1%usmn; 1%
Frequency( Synchronized Range) 46~54Hz
Frequency( Battery Mode) 50 ± 0.2 Hz; 0.2 Hz; 0.2 Hz 50Hz ± 0.05Hz; 0.05Hz; 0.05Hz
Current Crest Ratio 3:1
Harmonic Distortion <= 4% THD ( Linear Load) / <= 7% THD ( Non-Linear Load)r Load) <= 2% THD (Linear Load)/<= 6%THD(Non-Linear Load)r Load)
Output Waveform Pure Sinewave
EFFICIENCY
To AC Mode 85% 85% 85% > 88%
To Battery Mode 83% 83% 83% > 88%
BATTERY
Battery Type 12V/7Ah Depending on the capacity of external batteries 12V/7Ah Depending on the capacity of external batteries 12V/7Ah Depending on the capacity of external batteries 12V/7AH Depending on the capacity of external batteries
Numbers of Batteries 3 8 8 20
Backup Time(Full Load) ﹥5 minutesutes ﹥9 minutesutes ﹥5 minutesutes 8 minutes
Recharge Time 5 hours to 90% 5 hours to 90% 5 hours to 90% 7 hours to 90%
Charging Current (Max.) 1.0A 7A 1.0A 8A+/-1A 1.0A 8A+/-1A 2.0A 4.2A
Charging Voltage 41.1Vdc ± 0.6Vmn; 0.6Vmn; 0.6V 110Vdc ± 0.4Vmn; 0.4Vmn; 0.4V 274Vdc ± 1%Vsmn; 1%Vsmn; 1%V
External Battery type N/A 12V/7.2AH *6 N/A 12V/7.2AH *8 N/A 12V/7.2AH *8 N/A 12V/7.2AH *20
TRANSFER TIME
AC to DC Zero
Inverter to Bypass 2.5ms (Typical ) Zero
INDICATOR
Status Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault
AUDIBLE ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously Sounding
DIMENSION
UPS CaseD x W H(mm) 450x482.6x88 450x482.6x88 600x482.6x130
Battery Case D x W x H N/A 450*482.6*88 450*482.6*88 600*482.6*130
WEIGHT
UPS Case (kgs) 14(w / battery) 7 34.5(w / Battery) 15 35.5(W / Battery) 16 84(W / Battery) 35
Battery Rack (kgs) N/A 22.5 27.8 27.8 64.2
ENVIRONMENT
Operating Environment 0~40 Degrees Centigrade, 20~90% relative humidity (non-condensing)
Noise Level <45dB @ 1 Metereter 50dB @ 1 Meter <55dB @ 1 metereter
INTERFACE
Smart RS-232 Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC
SNMP (option) Power management from SNMP manager and web browser