IGBT Technology High Frequency R1kVA-6kVA Online UPS

IGBT Technology High Frequency R1kVA-6kVA Online UPS

200 USD

add to cart
Model NO. EH5110series
Type On-line
Frequency High Frequency
Output Voltage 220VAC
AVR Function Yes
Transfer Time 0
Transport Package Carton
Origin China
Phase Single Phase
Protection Overvoltage
Input Voltage 115-300VAC
Capacity 1-6kVA
Country of Origin China
Trademark MUST or OEM brand
Specification ISO, CE,
HS Code 8504402000
Sine wave output, Zero conversion time
Input zero frontline detection function, Bypass output
TVSS function, Input power correct
DC starting, Bypass protection
Automatic startup function, Long-term type power design
Strong ability to recharge long-term acting machine
Shelf-check function, Powerful anti-jamming
Can match generator
Support inductive load too
Winpower2000 monitoring software free downloads
Provide intelligent slot, Provide standard battery pack
Model EH1KR EH1KRS EH2KR EH2KRS EH3KR EH3KRS EH6KR EH6KRS
CAPACITY 1000VA/700W 2000VA/1400W 3000VA/2100W 6000VA/4200W
INPUT
Phase Single Phase with Ground
Frequency Range 50Hz:46~54Hz
Power Factor >=0.97 >=0.98
Voltage Range Base on load percentage (100%-80% / 80%-70% / 70%-60% / 60%-0%)
Line Low Transfer 160VAC/140VAC/120VAC/110VAC± 5VACmn; 5VACmn; 5VAC 176 ±3% VACn;3% VACn;3% VAC
Line Low Comeback 175VAC ± 5VACmn; 5VACmn; 5VAC 185 ± 3% VAC; 3% VAC; 3% VAC
Line High Transfer 300VAC± 5VACmn; 5VACmn; 5VAC 276 ± 3% VAC; 3% VAC; 3% VAC
Line High Comeback 285VAC± 5VACmn; 5VACmn; 5VAC 266 ± 3% VAC; 3% VAC; 3% VAC
OUTPUT
Phase Single
Voltage 220VAC/230VAC/240VAC
Voltage Regulation ± 2%usmn; 2%usmn; 2% ± 1%usmn; 1%usmn; 1%
Frequency( Synchronized Range) 46~54Hz
Frequency( Battery Mode) 50 ± 0.2 Hz; 0.2 Hz; 0.2 Hz 50Hz ± 0.05Hz; 0.05Hz; 0.05Hz
Current Crest Ratio 3:1
Harmonic Distortion <= 4% THD ( Linear Load) / <= 7% THD ( Non-Linear Load)r Load) <= 2% THD (Linear Load)/<= 6%THD(Non-Linear Load)r Load)
Output Waveform Pure Sinewave
EFFICIENCY
To AC Mode 85% 85% 85% > 88%
To Battery Mode 83% 83% 83% > 88%
BATTERY
Battery Type 12V/7Ah Depending on the capacity of external batteries 12V/7Ah Depending on the capacity of external batteries 12V/7Ah Depending on the capacity of external batteries 12V/7AH Depending on the capacity of external batteries
Numbers of Batteries 3 8 8 20
Backup Time(Full Load) ﹥5 minutesutes ﹥9 minutesutes ﹥5 minutesutes 8 minutes
Recharge Time 5 hours to 90% 5 hours to 90% 5 hours to 90% 7 hours to 90%
Charging Current (Max.) 1.0A 7A 1.0A 8A+/-1A 1.0A 8A+/-1A 2.0A 4.2A
Charging Voltage 41.1Vdc ± 0.6Vmn; 0.6Vmn; 0.6V 110Vdc ± 0.4Vmn; 0.4Vmn; 0.4V 274Vdc ± 1%Vsmn; 1%Vsmn; 1%V
External Battery type N/A 12V/7.2AH *6 N/A 12V/7.2AH *8 N/A 12V/7.2AH *8 N/A 12V/7.2AH *20
TRANSFER TIME
AC to DC Zero
Inverter to Bypass 2.5ms (Typical ) Zero
INDICATOR
Status Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault
AUDIBLE ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously Sounding
DIMENSION
UPS CaseD x W H(mm) 450x482.6x88 450x482.6x88 600x482.6x130
Battery Case D x W x H N/A 450*482.6*88 450*482.6*88 600*482.6*130
WEIGHT
UPS Case (kgs) 14(w / battery) 7 34.5(w / Battery) 15 35.5(W / Battery) 16 84(W / Battery) 35
Battery Rack (kgs) N/A 22.5 27.8 27.8 64.2
ENVIRONMENT
Operating Environment 0~40 Degrees Centigrade, 20~90% relative humidity (non-condensing)
Noise Level <45dB @ 1 Metereter 50dB @ 1 Meter <55dB @ 1 metereter
INTERFACE
Smart RS-232 Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC
SNMP (option) Power management from SNMP manager and web browser