| Model NO. | EH5110 1-6KVA |
| Type | On-line |
| Application | Communication |
| Standby Time | Standard Machine |
| Output Capacity | Medium Type |
| Brand | Must/OEM |
| AC-Mode to Battery-Mode | Zero Transfer Time |
| Battery Charge Control | Fast Charge at Constant Voltage |
| Weight | 8-41kg, Depends on Different Models |
| Power | 1kVA, 2kVA, 3kVA |
| Communication Interface | RS232 |
| Specification | CE ISO9001 certificates |
| HS Code | 8504402000 |
| Phase | Single Phase |
| Protection | Overvoltage |
| Classification | Lighting/Power |
| Standby UPS | Sine Wave Output UPS |
| Equipment Mode | Decentralized |
| Item | Rack Online UPS |
| Output Voltage | 110-300V or 120-276V, 208/220/230/240VAC |
| Wave Form | Pure Sine Wave |
| Color | Black |
| Wide Frequency | 40 - 70Hz |
| Trademark | MUST or OEM |
| Origin | China |
| Model | EH1KR | EH1KRS | EH2KR | EH2KRS | EH3KR | EH3KRS | EH6KR | EH6KRS |
| CAPACITY | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | 6000VA/4200W | ||||
| INPUT | ||||||||
| Phase | Single Phase with Ground | |||||||
| Frequency Range | 50Hz:46~54Hz | |||||||
| Power Factor | >=0.97 | >=0.98 | ||||||
| Voltage Range | Base on load percentage (100%-80% / 80%-70% / 70%-60% / 60%-0%) | |||||||
| Line Low Transfer | 160VAC/140VAC/120VAC/110VAC± 5VACmn; 5VACmn; 5VAC | 176 ±3% VACn;3% VACn;3% VAC | ||||||
| Line Low Comeback | 175VAC ± 5VACmn; 5VACmn; 5VAC | 185 ± 3% VAC; 3% VAC; 3% VAC | ||||||
| Line High Transfer | 300VAC± 5VACmn; 5VACmn; 5VAC | 276 ± 3% VAC; 3% VAC; 3% VAC | ||||||
| Line High Comeback | 285VAC± 5VACmn; 5VACmn; 5VAC | 266 ± 3% VAC; 3% VAC; 3% VAC | ||||||
| OUTPUT | ||||||||
| Phase | Single | |||||||
| Voltage | 220VAC/230VAC/240VAC | |||||||
| Voltage Regulation | ± 2%usmn; 2%usmn; 2% | ± 1%usmn; 1%usmn; 1% | ||||||
| Frequency( Synchronized Range) | 46~54Hz | |||||||
| Frequency( Battery Mode) | 50 ± 0.2 Hz; 0.2 Hz; 0.2 Hz | 50Hz ± 0.05Hz; 0.05Hz; 0.05Hz | ||||||
| Current Crest Ratio | 3:1 | |||||||
| Harmonic Distortion | <= 4% THD ( Linear Load) / <= 7% THD ( Non-Linear Load)r Load) | <= 2% THD (Linear Load)/<= 6%THD(Non-Linear Load)r Load) | ||||||
| Output Waveform | Pure Sinewave | |||||||
| EFFICIENCY | ||||||||
| To AC Mode | 85% | 85% | 85% | > 88% | ||||
| To Battery Mode | 83% | 83% | 83% | > 88% | ||||
| BATTERY | ||||||||
| Battery Type | 12V/7Ah | Depending on the capacity of external batteries | 12V/7Ah | Depending on the capacity of external batteries | 12V/7Ah | Depending on the capacity of external batteries | 12V/7AH | Depending on the capacity of external batteries |
| Numbers of Batteries | 3 | 8 | 8 | 20 | ||||
| Backup Time(Full Load) | ﹥5 minutesutes | ﹥9 minutesutes | ﹥5 minutesutes | 8 minutes | ||||
| Recharge Time | 5 hours to 90% | 5 hours to 90% | 5 hours to 90% | 7 hours to 90% | ||||
| Charging Current (Max.) | 1.0A | 7A | 1.0A | 8A+/-1A | 1.0A | 8A+/-1A | 2.0A | 4.2A |
| Charging Voltage | 41.1Vdc ± 0.6Vmn; 0.6Vmn; 0.6V | 110Vdc ± 0.4Vmn; 0.4Vmn; 0.4V | 274Vdc ± 1%Vsmn; 1%Vsmn; 1%V | |||||
| External Battery type | N/A | 12V/7.2AH *6 | N/A | 12V/7.2AH *8 | N/A | 12V/7.2AH *8 | N/A | 12V/7.2AH *20 |
| TRANSFER TIME | ||||||||
| AC to DC | Zero | |||||||
| Inverter to Bypass | 2.5ms (Typical ) | Zero | ||||||
| INDICATOR | ||||||||
| Status | Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault | |||||||
| AUDIBLE ALARM | ||||||||
| Battery Mode | Sounding every 4 seconds | |||||||
| Low Battery | Sounding every second | |||||||
| Overload | Sounding twice every second | |||||||
| Fault | Continuously Sounding | |||||||
| DIMENSION | ||||||||
| UPS CaseD x W H(mm) | 450x482.6x88 | 450x482.6x88 | 600x482.6x130 | |||||
| Battery Case D x W x H | N/A | 450*482.6*88 | 450*482.6*88 | 600*482.6*130 | ||||
| WEIGHT | ||||||||
| UPS Case (kgs) | 14(w / battery) | 7 | 34.5(w / Battery) | 15 | 35.5(W / Battery) | 16 | 84(W / Battery) | 35 |
| Battery Rack (kgs) | N/A | 22.5 | 27.8 | 27.8 | 64.2 | |||
| ENVIRONMENT | ||||||||
| Operating Environment | 0~40 Degrees Centigrade, 20~90% relative humidity (non-condensing) | |||||||
| Noise Level | <45dB @ 1 Metereter | 50dB @ 1 Meter | <55dB @ 1 metereter | |||||
| INTERFACE | ||||||||
| Smart RS-232 | Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC | |||||||
| SNMP (option) | Power management from SNMP manager and web browser | |||||||

MUST POWER LIMITED NEW FACTORY:
Shenzhen Must Power Limited established in 1998, which is a professional hi-tech enterprise specialized in Power Inverter,Solar Power, and Battery development, manufacturing, sales and after-service.
MUST ®®reg;® comprehensive product lines include: Power inverter, Solar inverter, Solar charge controller, Solar battery, Solar power Pack and some other related Solar products.

Factory Tour

Q1: How to choose a right inverter?
A1:Tell us your demand, then our sales will recommend a suitable inverter to you.
Q2: What's the difference between inverter and solar inverter?
A2: Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of inverter?
A4: One year warranty on Must-Solar product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.
We have a aftersales office in Pakistan Lahore, then we will open more and more office all over the world.
Welcome to contact me freely.
MUST Power Limited
Ada Ma
+86-132 5953 2991