Hospital Clinical Infant Incubator with CE (H-800)

Hospital Clinical Infant Incubator with CE (H-800)

900-901 USD

add to cart
Model NO. H-800
Certification CE
Group Infant
Medical Devices Reg./Record No. Gsyjxz20123540587
Temperature Rise Time ≤30min30min0min
Temperature Uniformity ≤1°ce;1°cg;ce;1°c
Trademark Healicom
Origin China
Type Infant Incubator
LCD Display Without LCD Display
Medical Device Regulatory Type Type 2
Temperature Control Mode Air Control
Temperature Variability ±0.5°csmn;0.5°cg;csmn;0.5°c
Air Temperature 20°c~37°cc~37°cg;cc~37°c
Specification ISO
HS Code 90189090
Standard Composition:
1. Servo Control Mode: air temp;
2. Instant Parameter Displaying: set temp, air temp, heat power rate;
3. Audible & Visual Alarms: power failure, sensor failure, higher/lower temp, air temperature override, fan failure;lure;lure;
4. Power failure reset memory and self-test function;
5. Hood with dual slope: 4 hand-ports
Specification:
Power Model H-800-1E 110 / 120 V ac, 50Hz / 60Hz
Model H-800-2E 220 / 240 V ac, 50Hz / 60Hz
Power Input ≤400VA00VA00VA
Refer to IEC60601-1, this equipment belongs to ClassI, Type BF
Its operation is continuous
Alarm Power Alarm Power Failure: Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle
Fan Alarm Fan Failure: Activates if Fan motor malfunctions
Sensor Alarm Air Sensor Failure: Air Sensor malfunction, refer unit to service
Deviation Alarm High Air Temperature: Activated if displayed Air Temperature is 15°C above set pointpointpoint
Low Air Temperature: Activated if displayed Air Temperature is 25°C below set pointpointpoint
Over Temperature Alarm Over Air Temperature: Activated when displayed Air Temperature was approach 38°C in Air Mode Mode Mode
System Alarm System Failure: Activated if Temperature Control System malfunctions
Temperature Control Range and Correlative Specifications Air Temperature 20°C~37°C~37°Ceg;C~37°C
Temperature Rise Time ≤30min0min0min
Temperature Variability ±0.5°Cmn;0.5°Ceg;Cmn;0.5°C
Temperature Uniformity ≤1°C;1°Ceg;C;1°C
Environment Requirement Environment Temperature Operation Temperature Range +20°C~+30°C+30°Ceg;C+30°C
Store Temperature Range -40°C~+55°C+55°Ceg;C+55°C
Environment Humidity Operation Humidity Range 30%~75%
Store Humidity Range 10%~100%
Atmospheric Pressure Range 700hPa~1060hPa
Other
Specifications
Noise Level Within Hood Environment ≤55dB(Environment noise below 45dB)5dB)5dB)
Carbon Dioxide (CO2) Level within the Hood Less than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress
Air Velocity Over Mattress less than 0.3m/s
Infant Bed Max Load 10kg
Transfusion Shelf Max Load 2kg
Factory Default Settings Temperature Control Mode Air Temperature Mode
Air Set Temperature: 32°Cdeg;Cdeg;C
Temperature Units:°Cdeg;Cdeg;C