Infant Radiant Warmer Medical Equipment (HNT-1000A)

Infant Radiant Warmer Medical Equipment (HNT-1000A)

1-1300 USD

add to cart
Model NO. HNT-1000A
Certification CE, ISO13485
Medical Device Regulatory Type Type 2
Temperature Control Mode Pre-Heat/Auto and Manual
Temperature Control Range 25°c~37°cc~37°cg;cc~37°c
Radiant Box Horizon Angle Adjust Range 0~±90° Step-Lesseg; Step-Lessg; Step-Less
Pressure Adjust Range 0~22kp(0~165mmhg)
White Phototherapy Light 1 Set
Specification ISO
HS Code 90189090
Theory Infant Radiant Warmer
Group Infant
Medical Devices Reg./Record No. Jyjxz20122260356
Environment Air Velocity of Flow <0.3m/S.3m/S
Neonate Resuscitation Bag 1 Set
7L Oxygen Cylinder (with Oxygen Manomete 2 Sets
Operating Noise ≤55db;55db55db
Trademark Healicom
Origin China
Standard composition
1. Servo Control Mode: air temperature
2. Instant Parameter Display: set temp, skin temp, heat power rate;
3. Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
4. Tilting Bed with Rotary Radiant Head
5. X-ray Cassette Tray under infant bed, examination light of high illuminance
6. Use anti-blast quartz infrared tube as radiant heating source.
Specifications HNT-1000 HNT-2000 HNT-2000B
Operational condition:
Environment temperature +18°C~+30°C+30°Ceg;C+30°C +18°C~+30°C+30°Ceg;C+30°C +18°C~+30°C+30°Ceg;C+30°C
Environment relative humidity 30%~75% 30%~75% 30%~75%
Environment air velocity of flow <0.3m/s3m/s <0.3m/s3m/s <0.3m/s3m/s
Power requirement ≤1000VA00VA00VA ≤1000VA00VA00VA ≤1000VA00VA00VA
Temperature control mode Auto Pre-heat/auto and manual Pre-heat/auto and manual
Temperature Control Range 25°C~37°C~37°Ceg;C~37°C 25°C~37°C~37°Ceg;C~37°C 25°C~37°C~37°Ceg;C~37°C
Temperature override mode to ----- 38°Cdeg;Cdeg;C 38°Cdeg;Cdeg;C
Temperature sensor accuracy ≤0.3°C.3°Ceg;C.3°C ≤0.3°C.3°Ceg;C.3°C ≤0.3°C.3°Ceg;C.3°C
Mattress temperature uniformity ≤2.0°C.0°Ceg;C.0°C ≤2.0°C.0°Ceg;C.0°C ≤2.0°C.0°Ceg;C.0°C
Temperature rise time ≤45 min min min ≤45 min min min ≤45 min min min
Heat output indicate 0~100% 0~100% 0~100%
Radiant box horizon angle adjust range 0~±90°step-lesseg;step-lesseg;step-less 0~±90° step-lessg; step-lessg; step-less 0~±90° step-lessg; step-lessg; step-less
Mattress Tray Size 68cm×56cmes;56cmes;56cm 68cm×56cmes;56cmes;56cm 68cm×56cmes;56cmes;56cm
Mattress tilt adjust range 0~±10° step-lessg; step-lessg; step-less 0~±10° step-lessg; step-lessg; step-less 0~±10° step-lessg; step-lessg; step-less
Mattress tray Max. load 10 kg 10 kg 10 kg
Transfusion pole Max. load 2 kg 2 kg 2 kg
Shelf Max. load 2 kg 2 kg 2 kg
X-ray Yes Yes Yes
RS-232 Connector ---- Yes Yes
Mattress to Radiant box 81 cm 81 cm 81 cm
Heater infrared wavelength 1~3 μmmu;mmu;m 1~3 μmmu;mmu;m 1~3 μmmu;mmu;m
APGAR Timer ----- Yes Yes
Alarms
Power failure alarm Yes Yes Yes
Sensor failure alarm Yes Yes Yes
Temperature deviation alarm ±1.0°Cmn;1.0°Ceg;Cmn;1.0°C ±1.0°Cmn;1.0°Ceg;Cmn;1.0°C ±1.0°Cmn;1.0°Ceg;Cmn;1.0°C
Over temperature alarm ≤38.0°C.0°Ceg;C.0°C ≤38.0°C/≤39.0°C/≤39.0°C0°C/≤39.0°C ≤38.0°C/≤39.0°C/≤39.0°C0°C/≤39.0°C
System failure alarm ----- Yes Yes
Low-pressure suction ------ ----- Yes
Pressure adjust range ------ ---- 0~22Kp(0~165mmHg)
Operating noise ------ ---- ≤55dB55dB55dB
White Phototherapy light ------ ------ 1 set
7L Oxygen cylinder (with oxygen manometer & oxygen flow meter)eter)eter) ------ ------ 2 sets
Neonate resuscitation bag ------ ------ 1 set
Packing size 110×90×110 cm×110 cm110 cm×110 cm 110 ×90 ×110 cm×110 cm110 cm×110 cm 110 ×90 ×110 cm×110 cm110 cm×110 cm
Net weight 85 kg 85 kg 95 kg
Gross Weight 115 kg 115 kg 125 kg