Infant Incubator Medical Infant Radiant Warmer

Infant Incubator Medical Infant Radiant Warmer

1-1300 USD

add to cart
Model NO. HNT-1000A
Certification CE, ISO13485
Environment Air Velocity of Flow <0.3m/S.3m/S
Neonate Resuscitation Bag 1 Set
7L Oxygen Cylinder (with Oxygen Manomete 2 Sets
Operating Noise ≤55db;55db55db
Trademark Healicom
Specification ISO
HS Code 90189090
Theory Infant Radiant Warmer
Temperature Control Mode Pre-Heat/Auto and Manual
Temperature Control Range 25°c~37°cc~37°cg;cc~37°c
Radiant Box Horizon Angle Adjust Range 0~±90° Step-Lesseg; Step-Lessg; Step-Less
Pressure Adjust Range 0~22kp(0~165mmhg)
White Phototherapy Light 1 Set
Transport Package Wooden Case
Origin China
Standard composition
1. Servo Control Mode: air temperature
2. Instant Parameter Display: set temp, skin temp, heat power rate;
3. Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
4. Tilting Bed with Rotary Radiant Head
5. X-ray Cassette Tray under infant bed, examination light of high illuminance
6. Use anti-blast quartz infrared tube as radiant heating source.
Technical specification
Power Model BNT-1000A-1E AC 110 / 120 V, 50Hz / 60Hz
Model BNT-1000A-2E AC 220 / 240V, 50Hz / 60Hz
Input Power ≤1000VA00VA00VA
Temperature control range and relative specification Control mode Auto mode
Temperature control range 25°C~37°C.37°C.g;C.37°C.
Skin temperature sensor measure range 20°C~42°C~42°Ceg;C~42°C
Deviation between sensor measure temperature and control temperature ≤0.5°C.5°Ceg;C.5°C
Skin Sensor Precision ≤0.3°C.3°Ceg;C.3°C
Bed surface temperature Uniformity ≤1°C;1°Ceg;C;1°C
Temperature Rise Time ≤45min5min5min
Bed tiltable continues adjustable in ±10°usmn;10°deg;usmn;10°
Alarm Sensor failure alarm Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.
Over temperature alarm Alarm with audible and visual when displayed temperature was approach 38°C.eg;C.eg;C.
Deviation alarm After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C. 1°C.g;C. 1°C.
Power failure alarm Alarm with audible and visual when power failure
Environment Temperature (It is a suggestion that please do not use outside of the allow environment.) Operate temperature range 18°C~30°C~30°Ceg;C~30°C
Store temperature range -20°C~+55°C+55°Ceg;C+55°C
Environment Humidity Operate humidity range 30%RH~75%RH
Store humidity range ≤93%RH3%RH3%RH
Atmospheric pressure Transport and Store atmospheric pressure range 500hPa~1060hPa
Operate atmospheric pressure range 700hPa~1060hPa
Stream velocity Ambit environment stream velocity ≤0.3m/s3m/s3m/s
With Intra-low-pressure suction machine