Hnt-1000A Medical Infant Radiant Warmer

Hnt-1000A Medical Infant Radiant Warmer

1350 USD

add to cart
Model NO. HNT-1000A
LCD Display Without LCD Display
Control Mode Auto Mode
Certificate ISO,CE
Input Power ≤1000va000va00va
Specification CE, ISO
HS Code 90189090
Certification CE, ISO13485
Group Children
Skin Temperature Sensor Measure Range 20°c~42°cc~42°cg;cc~42°c
Keyword Infant Radiant Warmer
Trademark Healicom
Origin China

Standard composition
Servo Control Mode: air temperature
Instant Parameter Display: set temp, skin temp, heat power rate;
Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
Tilting Bed with Rotary Radiant Head
X-ray Cassette Tray under infant bed, examination light of high illuminance
Use anti-blast quartz infrared tube as radiant heating source.
Technical specification

Power

Model BNT-1000-1E

AC 110 / 120 V, 50Hz / 60Hz

Model BNT-1000-2E

AC 220 / 240V, 50Hz / 60Hz

Input Power

≤1000VA00VA00VA

Temperature control range and relative specification

Control mode

Auto mode

Temperature control range

25°C~37°C.37°C.g;C.37°C.

Skin temperature sensor measure range

20°C~42°C~42°Ceg;C~42°C

Deviation between sensor measure temperature and control temperature

≤0.5°C.5°Ceg;C.5°C

Skin Sensor Precision

≤0.3°C.3°Ceg;C.3°C

Bed surface temperature Uniformity

≤1°C;1°Ceg;C;1°C

Temperature Rise Time

≤45min5min5min

Bed tiltable

continues adjustable in ±10°usmn;10°deg;usmn;10°

Alarm

Sensor failure alarm

Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power.

Over temperature alarm

Alarm with audible and visual when displayed temperature was approach 38°C.eg;C.eg;C.

Deviation alarm

After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C. 1°C.g;C. 1°C.

Power failure alarm

Alarm with audible and visual when power failure

Environment Temperature (It is a suggestion that please do not use outside of the allow environment.)

Operate temperature range

18°C~30°C~30°Ceg;C~30°C

Store temperature range

-20°C~+55°C+55°Ceg;C+55°C

Environment Humidity

Operate humidity range

30%RH~75%RH

Store humidity range

≤93%RH3%RH3%RH

Atmospheric pressure

Transport and Store atmospheric pressure range

500hPa~1060hPa

Operate atmospheric pressure range

700hPa~1060hPa

Stream velocity

Ambit environment stream velocity

≤0.3m/s3m/s3m/s

Add: Intra-low-pressure suction machine