| Model NO. | HNT-2000B |
| Function | Use for Babies |
| Certification | CE, ISO13485 |
| Group | Children |
| Instant Parameter Display | Set Temp, Skin Temp, Heat Power Rate; |
| Input Power | ≤1000va000va00va |
| Trademark | Healicom |
| Origin | China |
| Type | Infant Radiant Warmer |
| Theory | Radial |
| LCD Display | Without LCD Display |
| Temperature Control Mode | Pre-Heating Control, Servo Control & Manual Contr ContrContr |
| Power | AC 110 / 220 V, 50Hz / 60Hz |
| Keyword | Infant Radiant Warmer |
| Specification | CE, ISO |
| HS Code | 90189090 |
Power | AC 110 / 220 V, 50Hz / 60Hz | ||||
Input Power | ≤1000VA00VA00VA | ||||
Temperature control range and relative specification | Control mode | Pre-warm mode, manual mode, baby mode | |||
Temperature control range | 25°C~37°C, for set temperature ≤37°Cure ≤37°C7°Cure ≤37°C | ||||
37°C~38°C, for set temperature ﹥37°Cure >37°Ceg;Cure >37°C | |||||
Skin temperature sensor measure range | 20°C~42°C~42°Ceg;C~42°C | ||||
Deviation between sensor measure temperature and control temperature | ≤0.5°C.5°Ceg;C.5°C | ||||
Skin Sensor Precision | ≤0.3°C.3°Ceg;C.3°C | ||||
Bed surface temperature Uniformity | ≤1°C;1°Ceg;C;1°C | ||||
Temperature Rise Time | ≤45min5min5min | ||||
Bed tiltable | continues adjustable in ±10°usmn;10°deg;usmn;10° | ||||
Alarm | Sensor failure alarm | Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power. | |||
Over temperature alarm | Alarm with audible and visual when displayed temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature ﹥37°C, cut off power.7°C, cut off power..7°C, cut off power. | ||||
Deviation alarm | After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C. 1°C.g;C. 1°C. | ||||
Power failure alarm | Alarm with audible and visual when power failure | ||||
APGAR time | Alarm with audible when run between 50 seconds to 1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes. | ||||
Environment Temperature (It is a suggestion that please do not use outside of the allow environment.) | Operate temperature range | 18°C~30°C~30°Ceg;C~30°C | |||
Store temperature range | -20°C~+55°C+55°Ceg;C+55°C | ||||
Environment Humidity | Operate humidity range | 30%RH~75%RH | |||
Store humidity range | ≤93%RH3%RH3%RH | ||||
Atmospheric pressure | Transport and Store atmospheric pressure range | 500hPa~1060hPa | |||
Operate atmospheric pressure range | 700hPa~1060hPa | ||||
Stream velocity | Ambit environment stream velocity | ≤0.3m/s3m/s3m/s | |||
Specifications | HNT-1000 | HNT-2000 | HNT-2000B |
Environment temperature | +18°C~+30°C+30°Ceg;C+30°C | +18°C~+30°C+30°Ceg;C+30°C | +18°C~+30°C+30°Ceg;C+30°C |
Environment relative humidity | 30%~75% | 30%~75% | 30%~75% |
Environment air velocity of flow | <0.3m/s3m/s | <0.3m/s3m/s | <0.3m/s3m/s |
Power requirement | ≤1000VA00VA00VA | ≤1000VA00VA00VA | ≤1000VA00VA00VA |
Temperature control mode | Auto | Pre-heat,auto and manual | Pre-heat,auto and manual |
Temperature Control Range | 25°C~37°C~37°Ceg;C~37°C | 25°C~37°C~37°Ceg;C~37°C | 25°C~37°C~37°Ceg;C~37°C |
Temperature override mode to | ----- | 38°Cdeg;Cdeg;C | 38°Cdeg;Cdeg;C |
Temperature sensor accuracy | ≤0.3°C.3°Ceg;C.3°C | ≤0.3°C.3°Ceg;C.3°C | ≤0.3°C.3°Ceg;C.3°C |
Mattress temperature uniformity | ≤2.0°C.0°Ceg;C.0°C | ≤2.0°C.0°Ceg;C.0°C | ≤2.0°C.0°Ceg;C.0°C |
Temperature rise time | ≤45 min min min | ≤45 min min min | ≤45 min min min |
Heat output indicate | 0~100% | 0~100% | 0~100% |
Radiant box horizon angle adjust range | 0~±90°step-lesseg;step-lesseg;step-less | 0~±90° step-lessg; step-lessg; step-less | 0~±90° step-lessg; step-lessg; step-less |
Mattress Tray Size | 68cm×56cmes;56cmes;56cm | 68cm×56cmes;56cmes;56cm | 68cm×56cmes;56cmes;56cm |
Mattress tilt adjust range | 0~±10° step-lessg; step-lessg; step-less | 0~±10° step-lessg; step-lessg; step-less | 0~±10° step-lessg; step-lessg; step-less |
Mattress tray Max. load | 10 kg | 10 kg | 10 kg |
Transfusion pole Max. load | 2 kg | 2 kg | 2 kg |
Shelf Max. load | 2 kg | 2 kg | 2 kg |
X-ray | Yes | Yes | Yes |
RS-232 Connector | ---- | Yes | Yes |
Mattress to Radiant box | 81 cm | 81 cm | 81 cm |
Heater infrared wavelength | 1~3 μmmu;mmu;m | 1~3 μmmu;mmu;m | 1~3 μmmu;mmu;m |
APGAR Timer | ----- | Yes | Yes |
Power failure alarm | Yes | Yes | Yes |
Sensor failure alarm | Yes | Yes | Yes |
Temperature deviation alarm | ±1.0°Cmn;1.0°Ceg;Cmn;1.0°C | ±1.0°Cmn;1.0°Ceg;Cmn;1.0°C | ±1.0°Cmn;1.0°Ceg;Cmn;1.0°C |
Over temperature alarm | ≤38.0°C.0°Ceg;C.0°C | ≤38.0°C,≤39.0°C,≤39.0°C0°C,≤39.0°C | ≤38.0°C,≤39.0°C,≤39.0°C0°C,≤39.0°C |
System failure alarm | ----- | Yes | Yes |
Low-pressure suction | ------ | ----- | Yes |
Pressure adjust range | ------ | ---- | 0~22Kp(0~165mmHg) |
Operating noise | ------ | ---- | ≤55dB55dB55dB |
White Phototherapy light | ------ | ------ | 1 set |
7L Oxygen cylinder (with oxygen manometer & oxygen flow meter)eter)eter) | ------ | ------ | 2 sets |
Neonate resuscitation bag | ------ | ------ | 1 set |
Packing size | 110×90×110 cm×110 cm110 cm×110 cm | 110 ×90 ×110 cm×110 cm110 cm×110 cm | 110 ×90 ×110 cm×110 cm110 cm×110 cm |
Net weight | 85 kg | 85 kg | 95 kg |
Gross Weight | 115 kg | 115 kg | 125 kg |