| Model NO. | HA-3200A |
| Kind | Anesthesia Machine |
| Group | Adults&Childrenildrenldren |
| Source | Medical Oxygen and Nitrous Oxide |
| Medical Device Regulatory Type | Type 3 |
| Nominal-Voltage | LED Display Screen |
| Warranty | 12months |
| Mode | Pneumatically Powered and Electrically Controlled |
| Trademark | Healicom |
| Specification | CE, ISO |
| HS Code | 9018909090 |
| Type | Anaesthesia Machine |
| Certification | CE, ISO13485 |
| LCD Display | With LCD Display |
| Anesthesia | Closed; Semi-Closed; Semi-Open |
| Medical Devices Reg./Record No. | Gsyjxzz20093540256 |
| Suitable | Adult & Child ChildChild |
| Working Mode | Closed; Semi-Closed; Semi-Open |
| Certificate | CE ISO |
| Transport Package | Carton |
| Origin | Jiangsu, China |

| TECHNIQUES SPECIFICATIONS | |
| Physical specifications | |
| Screen | LED Display Screen |
| Suitable | Adult & ChildChildChild |
| Mode | pneumatically powered and electrically controlled system |
| Working Mode | Closed; Semi-Closed; Semi-Open |
| Circuit | Breathing circuit integrated standards |
| Tube | 2 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min |
| Trolley | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
| Drawer unit | ONE drawer totally extractable |
| Technical Specifications: | |
| Gas requirement | Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa. |
| Safety valve | <12.5 kPa kPa |
| Respiratory Rate | 4~40bpm |
| Flow meter | O2:0.1~10L/Min, N2O:0.1~10L/Min |
| Oxygen concentration in the mixed gas N2O/O2 | > 21% |
| Oxygen Flush: | 25~75 L/min |
| Maximum error of the pressure testing device | not exceed ± (4% of the full scale reading + 8% of the actual reading)reading)reading) |
| modes of ventilation | A/C,IPPV, SIPPV, MANUAL |
| I/E Ratio | 1:1.5; 1:2.0;1:2.5; 1:3 |
| Tidal Volume | 0~1500ML |
| Controlled ventilation and assisted ventilation switching time | 6s |
| Maximum safety pressure | ≤ 12.5 kPa kPa kPa |
| Pressure limit range | 0 ~ 6.0 kPa |
| Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa |
| ±0.2 kPa;0.2 kPa;0.2 kPa | |
| Tidal volume alarm: Audible and visual and with yellow and red color indicating | upper alarm: 50 to 2000ml,lower alarm: 0~1800ml |
| Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep ﹥120s120s |
| Operating conditions | |
| Ambient temperature | 10 ~ 40oC |
| Relative humidity | no higher than 80 % |
| Atmospheric pressure | 860 hPa ~ 1060 hPa |
| Power requirement: | 100-120 Vac, 50/60 Hz; |
| Air source requirement | Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa. |
| Attention: the AC power supply used for the anesthesia machine must be well grounded. | |
| Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. | |
| Configuration: | |
| Vaporizer | Enflurane/ Isoflurane(Option: Halothane) |
| Storage | |
| Ambient temperature | -15oC ~ +50oC |
| Relative humidity | no higher than 95 % |
| Atmospheric pressure | 86 kPa ~ 106 kPa. |
| It should be stored in a room without corrosive gas and well ventilated | |
| Package | |
| packaging box | comply with the requirement of GB/T 15464 |
| Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation | |
| Moisture protection and rain protection to ensure that product is protected from natural damage. | |
| Safety & AlarmAlarmAlarm | |
| Oxygen Alarm | It alarms when the oxygen supply from pipe or cylinders lower than 0.2MPa |
| Ventilation Volume Alarm | Lower: 0~12L/Min; Up: 18L/ Min |
| Power Alarm | It Alrmas while AC and DC supply failure ; Keep alraming time: ﹥120s120s |
| STANDARD CONFIGURATIONS | |
| QTY | NAME |
| 1 set | Main unit |
| 1 set | Built in ventilator |
| 1 set | 2-tube flow meter |
| 1 set | vaporizer |
| 1 set | Patient circuit |
| 1 set | bellow |
| 1 set | Na lime tank |
| 1 set | Diaphragm electronic sensor |
| 1 pic | Oxygen pressure reducer |
| 2 pics | A leather bag ( Blue) |
| 4 pics | Threaded pipe |
| 2 pics | mask |
| 1 set | Tools with the machine |
| 1 set | User Manual (English Version) |
| Optional | Patient Monitor |