Ha-3200A Ce Approved Anesthesia Machine

Ha-3200A Ce Approved Anesthesia Machine

1+
1830 USD
5+
1800 USD

add to cart
Model NO. HA-3200A
Kind Anesthesia Machine
Group Adults&Childrenildrenldren
Source Medical Oxygen and Nitrous Oxide
Medical Device Regulatory Type Type 3
Nominal-Voltage LED Display Screen
Warranty 12months
Mode Pneumatically Powered and Electrically Controlled
Trademark Healicom
Specification CE, ISO
HS Code 9018909090
Type Anaesthesia Machine
Certification CE, ISO13485
LCD Display With LCD Display
Anesthesia Closed; Semi-Closed; Semi-Open
Medical Devices Reg./Record No. Gsyjxzz20093540256
Suitable Adult & Child ChildChild
Working Mode Closed; Semi-Closed; Semi-Open
Certificate CE ISO
Transport Package Carton
Origin Jiangsu, China

Features:

1. Pneumatically driven electronically controlled system
2. Built-in ventilator, LED display screen
3. With 1 patient circuit for adult (Option: patient circuit for children).
4. 4-tube flowmeters, O2 & N2O;0.1 L/Min ~ 10 L/Min;/Min;/Min;
5. Vaporizer: Enflurane / Isoflurane / Sevoflurane;
(Option: Halothane)
6. Ptr:-10~10hPa;
7. Respiration Mode: IPPV, SIPPV, Manu
8. Tidal Volume: 50~1500mL;
9. Respiration Frequency: 4~40bpm;
10. I/E Ratio: 1:1.5~1:3
Prospective service and support
This H-01I Anesthesia Machine is an essential important anesthesia device in an operation room. Its function is to provide oxygen and anesthetic agent to a patient needing to go through an anesthesia operation and perform ventilation management.
A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.

TECHNIQUES SPECIFICATIONS
Physical specifications
Screen LED Display Screen
Suitable Adult & ChildChildChild
Mode pneumatically powered and electrically controlled system
Working Mode Closed; Semi-Closed; Semi-Open
Circuit Breathing circuit integrated standards
Tube 2 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min
Trolley Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Drawer unit ONE drawer totally extractable
Technical Specifications:
Gas requirement Medical oxygen and nitrous oxide with a pressure ranging from
O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa.
Safety valve <12.5 kPa kPa
Respiratory Rate 4~40bpm
Flow meter O2:0.1~10L/Min, N2O:0.1~10L/Min
Oxygen concentration in the mixed gas N2O/O2 > 21%
Oxygen Flush: 25~75 L/min
Maximum error of the pressure testing device not exceed ± (4% of the full scale reading + 8% of the actual reading)reading)reading)
modes of ventilation A/C,IPPV, SIPPV, MANUAL
I/E Ratio 1:1.5; 1:2.0;1:2.5; 1:3
Tidal Volume 0~1500ML
Controlled ventilation and assisted ventilation switching time 6s
Maximum safety pressure ≤ 12.5 kPa kPa kPa
Pressure limit range 0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa
±0.2 kPa;0.2 kPa;0.2 kPa
Tidal volume alarm: Audible and visual and with yellow and red color indicating upper alarm: 50 to 2000ml,lower alarm: 0~1800ml
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep ﹥120s120s
Operating conditions
Ambient temperature 10 ~ 40oC
Relative humidity no higher than 80 %
Atmospheric pressure 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz;
Air source requirement Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.
Attention: the AC power supply used for the anesthesia machine must be well grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Configuration:
Vaporizer Enflurane/ Isoflurane(Option: Halothane)
Storage
Ambient temperature -15oC ~ +50oC
Relative humidity no higher than 95 %
Atmospheric pressure 86 kPa ~ 106 kPa.
It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
Moisture protection and rain protection to ensure that product is protected from natural damage.
Safety & AlarmAlarmAlarm
Oxygen Alarm It alarms when the oxygen supply from pipe or cylinders lower than 0.2MPa
Ventilation Volume Alarm Lower: 0~12L/Min;
Up: 18L/ Min
Power Alarm It Alrmas while AC and DC supply failure ; Keep alraming time: ﹥120s120s
STANDARD CONFIGURATIONS
QTY NAME
1 set Main unit
1 set Built in ventilator
1 set 2-tube flow meter
1 set vaporizer
1 set Patient circuit
1 set bellow
1 set Na lime tank
1 set Diaphragm electronic sensor
1 pic Oxygen pressure reducer
2 pics A leather bag ( Blue)
4 pics Threaded pipe
2 pics mask
1 set Tools with the machine
1 set User Manual (English Version)
Optional Patient Monitor