400mA Medical X-ray Machine (KD400II)

400mA Medical X-ray Machine (KD400II)

bargain

add to cart
Model NO. KD400II
Type X Ray Equipment
Exposure Time 0.03-5s, 23 Shift
Diagnosis Table Ys09d Automatic, Adjusted Field of View
Distance of Focal Table 400mm
up and Down 600mm
Forward and Backward 300mm
Trademark MAYA
Origin Guangzhou China
Classification Imaging Diagnostic Equipment
Medical Devices Reg./Record No. Jyjxzz20062300402
X-ray Assembly Focus 1*1.2*2 Double Focal
Moving Table Automatic 700mm Distance Moving Lengthways
High of Table 820mm
Left and Right +-100mm
Way of Locking Electromagnetism Locking
Transport Package Export Wooden Box
1, 400mA Medical X-ray Machine(KD400II), X-ray equipment for hospitals, x ray unit -MAYA
400mA Medical X-ray Machine
1) Equipped with double diagnostic table and X-ray rubes, tube voltage is 125kV, tube currency is 400mA, single direct bridge full-wave commutation.
2) X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, X-ray tube over-hot protecionare provided, ensure X-ray tube run safely long time, improve accuracy of kV mA S.
3) Bigger scope of rotation diagnostic table, movable table muli-item spot-film device, easy to operate, radiation proof, ensure operate and the tested.
4) Radiography table can move lengthways and crossover, can loaded all kinds of radiography dark box, use conveniently and it is prety.
5) Applied in all kinds of hospital for radiography such as general body, beam filtration, and chest.
Department Technology parameters
High voltage generator control table and high voltage transform assemble Fluoroscopy Tube currency 0.3-5mA continuous currency
Tube voltage 45-110KV continuous voltage
Radiography Tube currency 50-400mA shift
Tube voltage 45-125KV continuous voltage
Exposure time 0.03-5s, 23 shift
Power Voltage 380V± 10%smn; 10%smn; 10%
Frequency 50Hz± 1Hzsmn; 1Hzsmn; 1Hz
Capacity ≥ 30KVA0KVA0KVA
Inner resistance ≤ 0.3Ω0.3ΩOmega;0.3Ω
X-ray assembly Type of x-ray XD51-20.40/125
Focus 1× 1.2× 2 double focal double focal double focal
Rated rotate speed of anode 2800r/min
Changed beam limited device Diagnosis table YS09D Automatic, adjusted field of view
Radiograph table YS11S Manually adjusted field of view, luminosity≥ 100LX00LX00LX
C15 Diagnostic table Rotate of table -15° ~0° ~90° automaticeg; automaticeg; automatic
Moving table Automatic 700mm distance moving lengthways
Distance of focal table 400mm
High of table 820mm
Spot film device Scope moving Up and down 600mm
Left and right ± 100mmn; 100mmn; 100mm
Forward and backward 300mm
Way of locking Electromagnetism locking
CDG
Multi function radiography table
Moving table Lengthways ± 600mmn; 600mmn; 600mm Electromagnetism locking
Across ± 120mmn; 120mmn; 120mm
Mobile beam filtration grid Grid density 28L/cm
Grid ratio 8: 1
Focusing distance 100cm
Scope of moving ≥ 600mm00mm00mm
Radiography item 5' × 7' , 8' × 10' , 10' × 12' , 11' × 14' ,0" , 10" × 12" , 11" × 14" ,uot; , 10" × 12" , 11" × 14" ,
12' × 15' , 14' × 14' , 14' × 17'uot; × 14" , 14" × 17"; × 14" , 14" × 17"
Distance from surface to film 75mm
Height of bed 700mm
Moving pillar ± 180° , per 90° orientation, moving lengthways ≥ 1500mmgthways ≥ 1500mm0mmgthways ≥ 1500mm
Bulb tube Rotate the cross arm± 180, ascend $ descend 1100mmd 1100mmd 1100mm