My-D011 200mA Diagnostic X-ray System

My-D011 200mA Diagnostic X-ray System

4700-5500 USD

add to cart
Model NO. MY-D011
Type X Ray Equipment
Medical Devices Reg./Record No. Jyjxzz20062300402
Max DC Output Voltage 100kv
Voltage 380V/220V
Transport Package Wooden Box
Origin China
Classification Imaging Diagnostic Equipment
Group All
Max DC Output Current 200mA
Moving Range of Bed Surface 640mm in Length, 200mmin Breadth
Trademark MAYA
Specification CE
MY-D011 200mA Diagnostic X-ray System

Detailed Product Description
1, MA200A 200mA Medical X-ray model
2, Special in radiography
3, tube currency is 200mA
MA200A 200mA Medical X-ray System
USE
General radiography, Filter-ray-filter radiograph
Unit Configuration
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator
MAIN CHARACTERISTICS
1, Single-table/single-tube
2, Rotary anode X-ray tube unit and tangential annular tube head
3, Single-phase full wave rectification high-voltage generator
4, Power voltage(v) radiograph kilovolt (KV). Step-less control electric mechanism
5, Filament stabilizer for X-ray tube unit and space charge compel mentor
6, Radiograph volume KV, MA and S. Grading and interlock protection
7, Adopt digital circuit timer. Grading according to R10 priority coefficient, (for more accurately controlling time)
8, HT primary, the zero controlled circuit of silicon-controlled rectifier of heavy power
9, Radiographic table can move in length an breadth
10, The radiographic table. Column and vibrating grid are in a whole without ceiling and floor rails bottom
ITEM CONTENTS INDEX
Demand of power supply Capacity Two-phase 30KVA
Voltage, Frequency 380V/220V ± 10%50HZ ± 0.5Hz ± 0.5Hz; 0.5Hz ± 0.5Hz
Intemal resistance 0.752Ω (380V) 0.25Ω (220V)Omega; (220V)Omega; (220V)
power supply Adjustable range 380± 10% at220V being adjustable continuouslyinuouslyinuously
Radiograph Voltage 50-100KV
50-100KV being adjustable continuously
current Small focus: 50mA100mA, Big focus: 50mA 100mA 200mA 300mA
time 0.04~6.35s 23grades together grading a according to R10 coefficient
High-voltage generator Capacity 20KVA(instantaneous)
Max DC output voltage 100KV
Max DC output current 200mA
X-Ray tube Model XD51.20-40/100
Focus Small focus 1× 1mm big focus2× 2mms2× 2mms; 2mms2× 2mm
Radiographic table Length× width× height of bed surfacef bed surfacef bed surface 2000mm× 665mm× 700mm× 700mm 700mm× 700mm
Moving range of bed surface 640mm in Length, 200mmin breadth
Ray-filter of table Travel in length ≥ 500mm00mm00mm
Grid density N=28
Convergence distance f. =100cm
Grid ratio r=8
Column of X-ray tube unit Moving Longitudinally along
Radiographic table
1000mm or 1800mm
Distance to friend as moving up and down (along column) 650~1800mm
Rotary around the center of cross arm ± 180°mn; 180°deg;mn; 180°
Rotary around the shaft line of
X-ray annular tubes
-10° ~60° ~ +120°; ~ +120°deg;; ~ +120°
Max size of cassette 356mm× 432mm (14″ × 17″ )rime; × 17″ ) 17″ )rime; × 17″ )