BMO210V Patient Monitor can monitor physiological parameter s: oxygen, ECG, body temperature, pulse, heart rate, blood pressure and so on. Reliable quality and stable health care system make policy makers more confidence . P owerful storage capacity, to ensure that you will not miss any clinical data. BMO210V Patient Monitor applicable to all types of dogs and cats in clinical care, vital signs parameters more comprehensive and more scientific. Features 12.1'' color TFT LCD screen with multi-channel wave forms display
Have patented technology of blood pressure measurement l
Anti-defibrillation, anti electric knife, ECG digital filtering
Super ECG anti-jamming capability
English and other 14 languages Operating System
Above 8000 Blood pressure storage and playback
Above 680 hour trend graph subsisting and playback
200 set alarm event storage and playback
12 hour wave line storage and playback
Built-in high-capacity rechargeable battery, with both AC and DC
Can be connected to a central monitoring system,supports wired and wireless , system software support network upgrade
Having a drug concentration calculations, breathing oxygen picture, ST segment analysis, large character interface, ECG full lead showed, abnormal heart rate analysis
Detection parameters: ECG / heart rate, noninvasive blood pressure / pulse rate, oxygen saturation, respiration, pulse, temperature
1.ECG Specifications Lead : three-lead or five-lead Three leads: RA, LA, LL, Mode :I, II, III Five leads: RA, LA, LL, RL, V, Mode : I, II, III, aVR, aVL, aVF, V Gain :
´´acute;´ 250, ´´acute;´ 500, ´´acute;´ 1000, ´´acute;´ 2000 Heart Rate Heart rate range : Large dogs: 15 ~ 300bpm (stroke / min) S mall dogs and puppies: 15 ~ 350 bpm (stroke / min) Accuracy: ± 1% or ± 1bpm, whichever is greaterever is greaterever is greater Resolution: 1 bpm (stroke / min) Sensitivity:
﹥ 200 uV (peak to peak)eak) Input impedance:
﹥ 5 (megohms)hms) B andwidth Diagnostic Mode: 0.05 ~ 130Hz Monitoring mode: 0.5 ~ 40Hz Operation mode: 1 ~ 20Hz CMRR Diagnostic mode:﹥ 90 dB0 dB Monitoring mode:﹥ 100 dB0 dB Operation mode:﹥ 100 dB0 dB Electrode polarization voltage range : 300mV Pacing pulse detection To meet the following conditions pacing pulse can be detected: Margin: ± 2 mV ~ ± 700mV ± 700mV; 700mV ± 700mV Width: 0.1ms ~ 2ms Rise time: 10us ~ 100μsmu;smu;s Pacing pulse suppression Margin: ± 2 mV ~ ± 700mV ± 700mV; 700mV ± 700mV Width: 0.1ms ~ 2ms Rise time: 10us ~ 100μsmu;smu;s Baseline recovery time : after defibrillation <3 secondsonds Signal Range : 8 mV (peak) Calibration signal:
1mV (peak), accuracy 5% ST segment detection measurements Measuring range: -2.0mV ~ + 2.0mV Accuracy: -0.8 mV ~ + 0.8mV ( error within ± 0.02mV or ± 10%or ± 10%mn; 10%or ± 10% ) Other ranges are not defined. 2. Respiratory Specifications M easurement method : RA-LL impedance Respiratory impedance detection range : 0.3 ~ 3Ω3Ωmega;3Ω Base impedance range : 200 ~ 4000ΩΩOmega;Ω Bandwidth : 0.1 ~ 2.5Hz Respiration rate Range:
Large dogs: 2 ~ 120BrPM small dogs and puppies: 2 ~ 150 BrPM Resolution: 1 BrPM Accuracy: 2 BrPM Suffocation alarm :
10 to 40 seconds 3. NIBP Specifications M easurement method:
Pulse wave oscillation Work Mode : manual / automatic / STAT M easurement interval for Automatic measurement mode 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes STAT measurement mode :
measurement time 5 minutes 4. SpO2 Specifications Oximetry Measuring range 0 to 100% Resolution 1% Accuracy of 70 to 100%: 2; 0% -69%: Not defined Pulse rate Measuring range 20 ~ 300bpm Resolution 1bpm Accuracy 3bpm 5. TEMP Specifications Temperature sensor :
YSI series, CYF series Number of channels 2 channels M easuring Range 0 ~ 50C Resolution 0.1C Accuracy 0.1C (sensor error not included) 6. IBP Specifications (optional) Number of channels 2 channels. P ressure t itle ART, PA, CVP, RAP, LAP, ICP, P1, P2. Pressure measurement range ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP -10 ~ 40 mmHg RAP -10 ~ 40 mmHg LAP -10 ~ 40 mmHg ICP -10 ~ 40 mmHg P1, P2 -10 ~ 300 mmHg Accuracy ± 1mmHg or ± 2%, the value is greater (not including sensor error)ng sensor error)g sensor error) Pressure Sensor Sensitivity 5 V / V / mmHg Impedance range 300 ~ 3000ΩΩOmega;Ω