Hm-8000A Vital Sign Portable Patient Monitor

Hm-8000A Vital Sign Portable Patient Monitor

2+
303-430 USD

add to cart
Model NO. HM-8000A
Type Patient/Fetal/Maternal Monitor
Group All People
Medical Devices Reg./Record No. Ssyjxz20132210387
Certificate CE ISO
NIBP Measuring Method Pulse Wave Oscillometry
SpO2 Range 0~100%
Warranty 12 Months
Keyword Monitor
Specification CE ISO
HS Code 9018193000
Classification Physiological Functions of Diagnosis and Monitoring Equipment
Certification CE, ISO13485
Medical Device Regulatory Type Type 2
Display Size 7 Inch LCD Display
Resp Measuring Method Ra-Ll Impedance
NIBP Work Mode Manual/Automatic/Stat
ECG Lead Mode 3-Lead or 5-Lead
Place of Orign China
Trademark healicom
Origin Jiangsu, China

Product description:
HM-8000A multi-parameter patient monitor is our newest product. The display is 7 inch high resolution color TFT. It is equipped with 4 parameters including ECG, NIBP, SpO2, RESP. These four parameters can be flexible. You can choose different combinations as you need. This monitor is built-in rechargeable lithium battery. The working capacity is 5 hours. IBP is optional.
Features & Benefits:fits:fits:
1. 4 Standard parameters: ECG, NIBP, SpO2, RESP.
2. 7 inch high resolution color TFT LCD display.
3. Real time S-T segment analysis, pace-maker detection.
4. Indication of Incorrect manipulation and malfunction analysis.
5. Patient info input management function
6. Multi-lead ECG waveforms display in phase.
7. Large volume of tabular and graphic trends information storage and easy to recall.
8. Capture dynamic waveforms.
9. Efficient resistance to interference of defibrillator and HF knife.
10. UP to 4 hours working capacity of built-in rechargeable lithium battery.
11. Unique accessory management cabinet.
12. Networking capacity.
13. Option: IBP
Technical parameters:
RESP
Measuring Method
RA-LL impedance
RESP Impedance Measuring Range 0.3~3ΩΩOmega;Ω
Base Impedance Range 200~4000ΩΩOmega;Ω
Bandwidth 0.1~2.5Hz RESP
NIBP
Measuring Method Pulse wave oscillometry
Work Mode Manual/Automatic/STAT
Measuring Interval of Automatic Measuring Mode
1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s)
Measuring Time of STAT Mode 5 minutes
PR range 40 - 240 bpm
SpO2
Range 0~100%
Resolution 1%
Precision 70~100%:2 DIGIT 0%~69%:no definition given
PR
Range 20~300bpm
Resolution 1bpm
Precision 3bpm
ECG
Lead configuration
Standard 3-lead or 5-lead
3-lead RA,LA,LL,Lead method:I,II,III
5-lead RA,LA,LL,RL,V,Lead method:I,II,III,aVR,aVL,aVF,
HR
Adult 15 ~ 300bpm (beat/minute)
Neonatal baby/children 15 ~ 350 bpm (beat/minute)
Precision ±1% or ±1bpm, the larger prevailslarger prevailslarger prevails
Resolution 1 bpm (beat/minute)
Sensitivity ﹥ 200 uV (Peak-to-peak value)lue)
Input Impedance ﹥ 5 (megohm)ohm)
Ration
Standard Configuration Options
1. SpO2 printer
2. SpO2, NIBP ETCO2
3. SpO2, NIBP, ECG IBP
4. SpO2, NIBP, TEMP, ECG wall mount
trolley