HM-8000C Portable Patient Monitor Multi-Parameter

HM-8000C Portable Patient Monitor Multi-Parameter

2+
450 USD

add to cart
Model NO. HM-8000C
Type Patient/Fetal/Maternal Monitor
Group All People
Medical Devices Reg./Record No. Ssyjxz20132210387
Certificate CE ISO
NIBP Modes Manual/Auto/Continuous
Temperature Range 0-500
Pulse Rate Range 20-254bpm
Warranty Period 1 Year
Specification CE ISO
HS Code 9018193000
Classification Physiological Functions of Diagnosis and Monitoring Equipment
Certification CE, ISO13485
Medical Device Regulatory Type Type 2
Display Size 12.1 Inch LCD Display
NIBP Measuring Method Oscillometry
ECG Lead Mode 3-Lead or 5-Lead
SpO2 Measurement Range 0-100%
Respiration Method Ra-Ll Impedance
Trademark healicom
Origin Jiangsu, China

Brief introduction
Patient monitor is a kind of instrument or system which is used to measure and control patients physiological parameters, which can be compared with known settings, if they are higher than know settings, the system will alarm.
Features
(1) 6 Standard parameters: ECG, 2-TEMP, NIBP, SpO2, RESP, PR/HR
(2) 12.1 inch high resolution color TFT LCD display
(3) Real time S-T segment analysis, pace-maker detection
(4) Indication of incorrect manipulation and malfunction analysis
(5) Patient info input management function
(6) Muti-lead ECG waveforms display in phase
(7) Large volume of tabular and praphic trends information storage and easy to recall
(8) Capture dynamic waveforms
(9) Up to 2 hours working capacity of built-in rechargeable lithium battery
(10) Unique accessory management cabinet
(11) Networking capacity
(12) Optional: ETCO2, thermal printer ,built-in recorder, cart, wall shelf
Parameters

NIBP
Method: Oscillometry
Modes: Manual/Auto/Continuous
Auto measure time: Adjustable
Measurement range:10-270mmHg
ECG Lead mode: 3-lead or 5-lead
Lead selection: I;II;III,avR;avL;avF
Heart rate range: Adult:15-300bpm;Pediatric/Neonatal:15-300bpm
ECG waveform: 2 channels
Accuracy: ±1 bpm or ±1%,which is greaterhich is greaterhich is greater
S-T segment detection; measurement range: -2.0mv~+2.0mv
Alarm: Yes, audible and visual alarm, alarm events review
SPO2 Measurement range:0-100%
Accuracy:70-100%,±2%,0-69%,upspecifiedpecifiedpecified
Auto measure time: Adjustable
Pulse Rate Range:20-254bpm
Accuracy: ±3bpmsmn;3bpmsmn;3bpm
Respiration Method: RA-LL impedance
Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm
Apnea alarm: Yes
Temperature Range:0-500
Accuracy: ± 0.10mn; 0.10mn; 0.10
Channel: Dual-channel
Main unit ECG cable
Spo2 probe
TEM Probe
NIBP Tube
Adult cuff
Power cable
Battery
User manual
ECG Electrodes
Warranty period: 1year for whole machine, half a year for parts
MOQ 1 unit
Delivery time Within 7 working days upon receipt the payment
Terms of payment T/T, L/C, western union