Medical Equipment Multi-Parameter Patient Monitor (HM-8000C)

Medical Equipment Multi-Parameter Patient Monitor (HM-8000C)

2+
450 USD

add to cart
Model NO. HM-8000C
Type Patient/Fetal/Maternal Monitor
Group All
Medical Devices Reg./Record No. Ysyjxzz20132210751
Screen 12.1 Inch High Resolution Color TFT LCD Display
Warranty 12months
NIBP Modes Manual/Auto/Continuous
NIBP Measurement Range 10-270mmhg
Pulse Rate Accuracy ±3bpmusmn;3bpmsmn;3bpm
Specification CE, ISO
HS Code 9018909090
Classification Physiological Functions of Diagnosis and Monitoring Equipment
Certification CE, ISO13485
Medical Device Regulatory Type Type 2
6 Standard Parameters ECG, 2-Temp, NIBP, SpO2, Resp, Pr/Hr
Certificate ISO, CE
NIBP Method Oscillometry
NIBP Auto Measure Time Adjustable
Pulse Rate Range 20-254bpm
Trademark Healicom
Origin Jiangsu, China
Brief introduction:
Patient monitor is a kind of instrument or system which is used to measure and control patients physiological parameters, which can be compared with known settings, if they are higher than know settings, the system will alarm.
Features:
6 Standard parameters: ECG, 2-TEMP, NIBP, SpO2, RESP, PR/HR
12.1 inch high resolution color TFT LCD display
Real time S-T segment analysis, pace-maker detection
Indication of incorrect manipulation and malfunction analysis
Patient info input management function
Muti-lead ECG waveforms display in phase
Large volume of tabular and praphic trends information storage and easy to recall
Capture dynamic waveforms
Up to 2 hours working capacity of built-in rechargeable lithium battery
Unique accessory management cabinet
Networking capacity
Optional: ETCO2, thermal printer ,built-in recorder, cart, wall shelf
Parameters:
NIBP Method: Oscillometry
Modes: Manual/Auto/Continuous
Auto measure time: Adjustable
Measurement range:10-270mmHg
ECG Lead mode: 3-lead or 5-lead
Lead selection: I;II;III,avR;avL;avF
Heart rate range: Adult:15-300bpm;Pediatric/Neonatal:15-300bpm
ECG waveform: 2 channels
Accuracy: ±1 bpm or ±1%,which is greaterhich is greaterhich is greater
S-T segment detection; measurement range: -2.0mv~+2.0mv
Alarm: Yes, audible and visual alarm, alarm events review
SPO2 Measurement range:0-100%
Accuracy:70-100%,±2%,0-69%,upspecifiedpecifiedpecified
Auto measure time: Adjustable
Pulse Rate Range:20-254bpm
Accuracy: ±3bpmsmn;3bpmsmn;3bpm
Respiration Method: RA-LL impedance
Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm
Apnea alarm: Yes
Temperature Range:0-500
Accuracy: ± 0.10mn; 0.10mn; 0.10
Channel: Dual-channel
Main unit ECG cable
Spo2 probe
TEM Probe
NIBP Tube
Adult cuff
Power cable
Battery
User manual
ECG Electrodes
Warranty period: 1year for whole machine, half a year for parts
MOQ 1 unit
Delivery time Within 7 working days upon receipt the payment