15 Inch Screen Multi-Parameter Medical Patient Monitor

15 Inch Screen Multi-Parameter Medical Patient Monitor

2+
595 USD

add to cart
Model NO. HM-8000D
Type Patient/Fetal/Maternal Monitor
Group All
Screen 15 Inch High Resolution Color TFT LCD Display
Warranty 12months
NIBP Modes Manual/Auto/Continuous
NIBP Measurement Range 10-270mmhg
Pulse Rate Accuracy ±3bpmusmn;3bpmsmn;3bpm
Specification CE, ISO
HS Code 9018909090
Classification Physiological Functions of Diagnosis and Monitoring Equipment
Certification CE, ISO13485
6 Standard Parameters ECG, 2-Temp, NIBP, SpO2, Resp, Pr/Hr
Certificate ISO, CE
NIBP Method Oscillometry
NIBP Auto Measure Time Adjustable
Pulse Rate Range 20-254bpm
Trademark Healicom
Origin Jiangsu, China
HM-8000D multi-parameter patient monitor is a robust patient monitor, small enough to move around, yet flexible enough to adapt to your particular needs. With a variety of optional extras, including arrhythmia and ST analysis, EtCO2 measurement and double IBP, HM-8000D multi-parameter patient monitor is configurable to suit your requirements.
Features for Patient Monitor:
6 Standard parameters: ECG, 2-TEMP, NIBP, SpO2, RESP, PR/HR
15 inch high resolution color TFT LCD display
Real time S-T segment analysis, pace-maker detection
Indication of incorrect manipulation and malfunction analysis
Patient info input management function
Muti-lead ECG waveforms display in phase
400 NIBP measurement data can be stored and recall
96 hours graphic and tabular trends of all parameters
Large volume of tabular and praphic trends information storage and easy to recall
Capture dynamic waveforms
Up to 2 hours working capacity of built-in rechargeable lithium battery
Unique accessory management cabinet
Networking capacity
Option: ETCO2, Built-in recorder, cart, wall shelf
Parameters for Patient Monitor:
NIBP Method: Oscillometry
Modes: Manual/Auto/Continuous
Auto measure time: Adjustable
Measurement range:10-270mmHg

ECG

Lead mode: 3-lead or 5-lead
Lead selection: I;II;III,avR;avF;avL
Heart rate range: Adult:15-300bpm;Pediatric/
Neonatal:15-300bpm
ECG waveform: 2 channels
Accuracy: ±1 bpm or ±1%,which is greaterhich is greaterhich is greater
S-T segment detection; measurement range: -2.0mv~+2.0mv
Alarm: Yes, audible and visual alarm, alarm events review
SPO2 Measurement range:0-100%
Accuracy:70-100%,±2%,0-69%,upspecifiedpecifiedpecified
Auto measure time: Adjustable

Pulse Rate
Range:20-254bpm
Accuracy: ±3bpmsmn;3bpmsmn;3bpm

Respiration
Method: RA-LL impedance
Range:Adult:0-120rpm;pediatric/neonatal:0-150rpm
Apnea alarm: Yes
Temperature Range:0-500
Accuracy: ± 0.10mn; 0.10mn; 0.10
Channel: Dual-channel
Main unit ECG cable
SPo2 probe
TEM Probe
NIBP Tube
Adult cuff
Power cable
Battery
User manual
ECG Electrodes
Warranty Period: 1year