China Factory 12 Inch Multi-Parameter Patient Monitor

China Factory 12 Inch Multi-Parameter Patient Monitor

2+
400-430 USD

add to cart
Model NO. HM-8000B
Type Patient/Fetal/Maternal Monitor
Group All
Screen 12 Inch High Resolution Color TFT LCD Display
Trademark Healicom
Specification CE, ISO
HS Code 9018909090
Classification Physiological Functions of Diagnosis and Monitoring Equipment
Certification CE, ISO13485
6 Standard Parameters ECG, 2-Temp, NIBP, SpO2, Resp, Pr/Hr
Certificate ISO, Ce
Transport Package Carton
Origin Jiangsu, China
Brief introduction:
Patient monitor is a kind of instrument or system which is used to measure and control patients physiological parameters, which can be compared with known settings, if they are higher than know settings, the system will alarm.
Features:
• 6 Standard parameters: ECG, 2-TEMP, NIBP, SpO2, RESP, PR/HR PR/HR PR/HR
• 12.1 inch high resolution color TFT LCD displayisplayisplay
• Real time S-T segment analysis, pace-maker detectionectionection
• Indication of incorrect manipulation and malfunction analysisalysisalysis
• Patient info input management functionnctionnction
• Muti-lead ECG waveforms display in phase phase phase
• Large volume of tabular and praphic trends information storage and easy to recallrecallrecall
• Capture dynamic waveformseformseforms
• Up to 2 hours working capacity of built-in rechargeable lithium batteryatteryattery
• Unique accessory management cabinetabinetabinet
• Networking capacitypacitypacity
• Optional: IBP, 2-IBP, ETCO2, thermal printer, built-in recorder, cart, wall shelf shelf shelf
NIBP
  • Method: Oscillometry
  • Modes: Manual/Auto/Comtinuous
  • Auto measure time: Adjustable
  • Measurement range: 10-270mmHg

ECG
  • Lead mode: 3-lead or 5-lead
  • Lead selection: I;II;III,avR;avF;V
  • Heart rate range: Adult: 15-300bpm; Pediatric/Neonatal:15-300bpm
  • ECG waveform: 2 channels
  • Accuracy: ±1 bpm or ±1%, which is greaterhich is greaterhich is greater
  • S-T segment detection; measurement range: -2.0mv~2.0mv
  • Alarm: Yes, audible and visual alarm, alarm events review

SPO2
  • Measurement range: 0-100%
  • Accuracy: 70-100%,±2%,0-69%,upspecifiedpecifiedpecified
  • Auto measure time: Adjustable

Pulse Rate
  • Range: 20-254bpm
  • Accuracy: ±3bpmsmn;3bpmsmn;3bpm

Respiration
  • Method: RA-LL impedance
  • Range: Adult: 0-120rpm; pediatric/neonatal: 0-150rpm
  • Apnea alarm: Yes

Temperature
  • Range: 0-500
  • Accuracy: ± 0.10mn; 0.10mn; 0.10
  • Channel: Dual-channel

Standard configuration:
  • Main unit, ECG cable, spo2 probe, TEM Probe, NIBP Tube, Adult cuff, Power cable, Battery, user manual, ECG Electrodes.