Hc-8000c Biphasic Defibrillator with Monitor

Hc-8000c Biphasic Defibrillator with Monitor

1+
2770 USD
5+
2750 USD

add to cart
Model NO. HC-8000C
Certification CE, ISO13485
LCD Display Without LCD Display
Medical Devices Reg./Record No. Ysyjxzz20132210751
Dimensions L320xw205xh410
Certificate CE, ISO
Optional Recorder, Li-ion Battery
Trademark Healicom
Specification CE, ISO
HS Code 9018909090
Type Defibrillator
Group Adult and Children
Medical Device Regulatory Type Type 2
Main Unit Portable
Weight 9.8kg
Warranty 12months
Defibrillator Type Manual, Synchronized, Asynchronized
Transport Package Carton
Origin Jiangsu, China

DEFIBRILLATOR (Biphasic)
Technical specifications
1) Defibrillator type: Manual, Synchronized, Asynchronized,
2) Energy accuracy: ∠+1%g;+1%g;+1%
3) Energy selection: 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of 50)
4) Charging time: Maximum 10 seconds to 360 Joules
5) Standard Adult/Pediatric Paddles: Reusable external adult paddles (pediatric paddles integrated)
Power requirements
(a) AC Power supply 100V~240V, 50Hz/60 Hz
(b) Vehicle Voltage (Option) DC 12V
Internal Battery Backup
(1) Battery type: Rechargeable lead-acid battery (12V 2.0Ah X2)
(2) Charging time: Time-Minimum of 4 hours for full charging
(3) Battery charging: During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication: Red LED
(5) Battery Capacity: 100% of the battery will provide 120-min monitoring; and 35 discharges at 360 joules.
Display
LCD Dimensions 7-inch
Type High resolution true-color graphic
Resolution 480*234
Standard parameter & configurationationation
ECG/ RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
Optional parameter
Recorder, Li-ion battery (11.1V 4Ah X2)
ECG
ECG lead: I, II, III, AVR, AVL, AVF, V1~V6
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: Yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurement method: Thoracic impedance
NIBP
Working mode: Manual/Automatic/stat (5 minutes)
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal
Temperature
Measurement range 20~45°Cdeg;Cdeg;C
Resolution 0.1°Cdeg;Cdeg;C
Pulse Oximetry (spO2)
Display: Spo2 value, pulse histogram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe: Standard adult finger clip
Optional pediatric Y-type clip and neonatal wrap
Pulse range
Pulse range: 0-255bpm
Physical characteristics
Main unit Portable
Dimensions(mm) L320xW205xH410
Weight 9.8kg