CE Quality Infant Incubator (THR-II 970)

CE Quality Infant Incubator (THR-II 970)

bargain

add to cart
Model NO. THR-II 970
Certificate CE and ISO
Control Modes Two Methods
Inclination Bassine Available
Specification 1085mm*640mm*915mm
OEM Available
Warranty One Year
Weight System Available
Trademark THR
Origin China
CE Quality! Infant Incubator (THR-II970)
Brief Introduction:
--Air mode and baby mode controlled by micro-computer;
--Humidity control system and Oxygen concentration control system;
--Set temperature, air temperature, baby temperature, humidity and oxygen are displayed separately;
--﹥37degree temperature set function;ion;
--Failure alarm indication;
--Embedded integrated sensor box;
--integrated water reservoir in the shape of drawer;
--Double wall hood, automatic air circulation device;
--Inclination of bassinet is adjustable;
--RS-232 connector.
--Weighing system and Monitor shelf are optional.
Standard Configuration:
The hood,
The base,
The mobile cabinet,
The controller,
I. V pole,
Shelf,
With oxygen concentration control system.
Optional Configurations:
Fixed neonate bilirubin phototherapy equipment model: XHZ-90 (with blue fluorescent lamps)
Fixed neonate bilirubin phototherapy equipment with LED model: XHZ-90L (with LED bulbs)
Vertical height adjustment stand (VHA stand)
Weighing system.
Technical Parameters:
Power supply AC220V-230V/50Hz
Max power output 1000VA
Mode of control Air model and baby model controlled by micro-computer
Air temperature control range 25° C -37° C (override mode 37-39° C)37-39° C); C)37-39° C)
Baby temperature control range 34-37° C (override mode 37-38° C)8° C); C)8° C)
Accuracy of skin temperature sensor ≤ 0.3° C3° Cg; C3° C
Temperature variability ≤ 0.5° C5° Cg; C5° C
Temperature uniformity ≤ 0.8° C (mattress is on the horizontal position)osition)osition)
Inclination of the bassinet ± 12°smn; 12°deg;smn; 12°
Noise inside hood ≤ 55dB(A) (Environment noise ≤ 45dB(A))5dB(A))5dB(A))
Failure alarm Over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, sensor box position alarm, low water alarm, tank position alarm and system alarm.
Humidity display range 0% RH-99%RH
Humidity control range 0% RH-99%RH
Accuracy of humidity ± 10% RH; 10% RH; 10% RH
Indication range of oxygen concentration 0%-99%
Control range of oxygen concentration 20%-60%
Accuracy of oxygen concentration ± 3%usmn; 3%usmn; 3%
Environmental Temperature:
Operating range: 20° C-30° C30° Cg; C30° C
(set temperature should be higher 3° C than the environment temperature)ture)ture)
Ambient air movement rate: ≤ 0.3m/s3m/s3m/s
Package Information:
Each unit is package into two cartons
Main body: 1085mm*640mm*915mm, 68kg.
Cabinet: 1125mm*665mm*730mm