Flowmeters with Two Vaporizer Multifunctional Anesthesia (AM-JL01B)

Flowmeters with Two Vaporizer Multifunctional Anesthesia (AM-JL01B)

bargain

add to cart
Model NO. AM-JL01B
Kind ICU
Group All
Medical Device Regulatory Type Gxzz1234567890
Trademark AMISMED
HS Code 90189070
Type Anaesthesia Machine
Certification CE
LCD Display With LCD Display
Display 5.4
Origin China
AM-JL01B with 2 vaporizers Multifunctional Anesthesia machine
Pneumatically driven and electrically controlled system
Built-in ventilator, 5.4' LCD display screenscreen
Closed; Semi-Closed; Semi-Open wotking mode
Applied for Adult and Pediatric
Main technical specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. MPa. MPa.
4-tubes Flowmeters, O2 & N2O; 0.1L/Min ~ 10L / Min;
Oxygen Flush: 25~75 L / Min
Respiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,MANUAL
Tidal Volume: Display range: 0~1500ml ; Adjustable range: 50~1500ml
I/E Ratio: 4:1 ~ 1:10
Two vaporizers: Enflurane/ Isoflurane/Sevoflurane/Halothane
Vaporizer Setting Range: 0.5%~5%
Respiration Frequency : 1~99 bpm;
Ptr: -1.0kPa ~ 1.0 kPa
CO2 absorber capacity : 1 kg
Optional: Patient monitor
Alarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea,
AC power malfunction,Battery low power.
AM-JL01B with 1 vaporizer Multifunctional Anesthesia machine
Pneumatically driven and electrically controlled system
Built-in ventilator, 5.4' LCD display screenscreen
Closed; Semi-Closed; Semi-Open wotking mode
Applied for Adult and Pediatric
Main technical specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. MPa. MPa.
4-tubes Flowmeters, O2 & N2O; 0.1L/Min ~ 10L / Min;
Oxygen Flush: 25~75 L / Min
Respiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,MANUAL
Tidal Volume: Display range: 0~1500ml ; Adjustable range: 50~1500ml
I/E Ratio: 4:1 ~ 1:10
One vaporizer: Enflurane/ Isoflurane/Sevoflurane/Halothane
Vaporizer Setting Range: 0.5%~5%
Respiration Frequency : 1~99 bpm;
Ptr: -1.0kPa ~ 1.0 kPa
CO2 absorber capacity : 1 kg
Optional: Patient monitor
Alarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea,
AC power malfunction,Battery low power.

AM-JL01B with 1 vaporizer Multifunctional Anesthesia machine
Pneumatically driven and electrically controlled system
Built-in ventilator, 5.4' LCD display screenscreen
Closed; Semi-Closed; Semi-Open wotking mode
Applied for Adult and Pediatric
Main technical specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. MPa. MPa.
4-tubes Flowmeters, O2 & N2O; 0.1L/Min ~ 10L / Min;
Oxygen Flush: 25~75 L / Min
Respiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,MANUAL
Tidal Volume: Display range: 0~1500ml ; Adjustable range: 50~1500ml
I/E Ratio: 4:1 ~ 1:10
One vaporizer: Enflurane/ Isoflurane/Sevoflurane/Halothane
Vaporizer Setting Range: 0.5%~5%
Respiration Frequency : 1~99 bpm;
Ptr: -1.0kPa ~ 1.0 kPa
CO2 absorber capacity : 1 kg
Optional: Patient monitor
Alarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,