Flowmeters with Two Vaporizer Multifunctional Anesthesia (AM-JL850)

Flowmeters with Two Vaporizer Multifunctional Anesthesia (AM-JL850)

bargain

add to cart
Model NO. AM-JL850
Kind ICU
Group All
Source Oxygen
Display 10.4′′ / 8.4′′prime; / 8.4′′ime;′prime; / 8.4′′
Origin China
Type Anaesthesia Machine
Certification CE, SGS, ISO13485
LCD Display With LCD Display
Medical Device Regulatory Type Gxzz1234567890
Trademark AMISMED
HS Code 90189070
AM-JL850 Multifunctional Anesthesia machine
Pneumatically driven and electrically controlled system
Built-in ventilator, 10.4' LCD display screenscreen
Closed; Semi-Closed; Semi-Open wotking mode
Applied for Adult and Pediatric
Main technical specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. MPa. MPa.
5-tubes Flowmeters, O2 & N2O & Air ; 0.1L/Min ~ 10L / Min; Min; Min;
Oxygen Flush: 25~75 L / Min
Respiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,PCV, VCV,PEEP,SIGH,MANUAL
Tidal Volume: Adjustable range: 50 ~ 1500 ml, Display range:0~2000ml
I/E Ratio: 8:1 ~ 1:10
Two vaporizers: Enflurane/ Isoflurane/Sevoflurane/Halothane
Vaporizer Setting Range: 0.5%~5%
Respiration Frequency : 1~100 bpm;
Lung compliance: ≤30 mL / kPa kPa kPa
IMV frequency: 1~20 bpm;
PEEP: 0 ~ 2.0 kPa
Ptr: -1.0kPa ~ 2.0 kPa
CO2 absorber capacity : 1 kg
Inspiratory Plateau: 0~1 S ;
O2 Concentration: 21%~100%
Optional: Patient monitor
Alarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea,
oxygen concentration, AC power malfunction,Battery low power.
AM-JL850 Multifunctional Anesthesia machine
Pneumatically driven and electrically controlled system
Built-in ventilator, 8.4' LCD display screenscreen
Closed; Semi-Closed; Semi-Open wotking mode
Applied for Adult and Pediatric
Main technical specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. MPa. MPa.
5-tubes Flowmeters, O2 & N2O & Air ; 0.1L/Min ~ 10L / Min; Min; Min;
Oxygen Flush: 25~75 L / Min
Respiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,VCV,PEEP,SIGH,MANUAL (Optional: PCV )
Tidal Volume: Adjustable range: 50 ~ 1500 ml, Display range:0~2000ml
I/E Ratio: 8:1 ~ 1:10
Two vaporizers: Enflurane/ Isoflurane/Sevoflurane/Halothane
Vaporizer Setting Range: 0.5%~5%
Respiration Frequency : 1~100 bpm;
Lung compliance: ≤30 mL / kPa kPa kPa
IMV frequency: 1~20 bpm;
PEEP: 0 ~ 2.0 kPa
Ptr: -1.0kPa ~ 2.0 kPa
CO2 absorber capacity : 1 kg
Inspiratory Plateau: 0~1 S ;
O2 Concentration: 21%~100%
Optional: Patient monitor
Alarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea,
oxygen concentration, AC power malfunction,Battery low power.