add to cart| Model NO. | AM-JL850 |
| Kind | ICU |
| Group | All |
| Source | Oxygen |
| Display | 10.4′′ / 8.4′′prime; / 8.4′′ime;′prime; / 8.4′′ |
| Origin | China |
| Type | Anaesthesia Machine |
| Certification | CE, SGS, ISO13485 |
| LCD Display | With LCD Display |
| Medical Device Regulatory Type | Gxzz1234567890 |
| Trademark | AMISMED |
| HS Code | 90189070 |
| |
![]() | |
| |
| Built-in ventilator, 10.4' LCD display screenscreen | |
| Closed; Semi-Closed; Semi-Open wotking mode | |
| Applied for Adult and Pediatric | |
| Main technical specifications: | |
| Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. MPa. MPa. | |
| 5-tubes Flowmeters, O2 & N2O & Air ; 0.1L/Min ~ 10L / Min; Min; Min; | |
| Oxygen Flush: 25~75 L / Min | |
| Respiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,PCV, VCV,PEEP,SIGH,MANUAL | |
| Tidal Volume: Adjustable range: 50 ~ 1500 ml, Display range:0~2000ml | |
| I/E Ratio: 8:1 ~ 1:10 | |
| Two vaporizers: Enflurane/ Isoflurane/Sevoflurane/Halothane | |
| Vaporizer Setting Range: 0.5%~5% | |
| Respiration Frequency : 1~100 bpm; | |
| Lung compliance: ≤30 mL / kPa kPa kPa | |
| IMV frequency: 1~20 bpm; | |
| PEEP: 0 ~ 2.0 kPa | |
| Ptr: -1.0kPa ~ 2.0 kPa | |
| CO2 absorber capacity : 1 kg | |
| Inspiratory Plateau: 0~1 S ; | |
| O2 Concentration: 21%~100% | |
| Optional: Patient monitor | |
| Alarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea, | |
| oxygen concentration, AC power malfunction,Battery low power. |
| |
![]() | |
| |
| Built-in ventilator, 8.4' LCD display screenscreen | |
| Closed; Semi-Closed; Semi-Open wotking mode | |
| Applied for Adult and Pediatric | |
| Main technical specifications: | |
| Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2 & NO2: 0.32~0.6 MPa. MPa. MPa. | |
| 5-tubes Flowmeters, O2 & N2O & Air ; 0.1L/Min ~ 10L / Min; Min; Min; | |
| Oxygen Flush: 25~75 L / Min | |
| Respiration Mode: A/C,IPPV,SIPPV,IMV,SIMV,VCV,PEEP,SIGH,MANUAL (Optional: PCV ) | |
| Tidal Volume: Adjustable range: 50 ~ 1500 ml, Display range:0~2000ml | |
| I/E Ratio: 8:1 ~ 1:10 | |
| Two vaporizers: Enflurane/ Isoflurane/Sevoflurane/Halothane | |
| Vaporizer Setting Range: 0.5%~5% | |
| Respiration Frequency : 1~100 bpm; | |
| Lung compliance: ≤30 mL / kPa kPa kPa | |
| IMV frequency: 1~20 bpm; | |
| PEEP: 0 ~ 2.0 kPa | |
| Ptr: -1.0kPa ~ 2.0 kPa | |
| CO2 absorber capacity : 1 kg | |
| Inspiratory Plateau: 0~1 S ; | |
| O2 Concentration: 21%~100% | |
| Optional: Patient monitor | |
| Alarm parameters: upper/lower limit of airway pressure,tital volume exceed limitation,no tidal volume output,apnea, | |
| oxygen concentration, AC power malfunction,Battery low power. |