ICU Ventilator with Ce Approved (AM-900B)

ICU Ventilator with Ce Approved (AM-900B)

bargain

add to cart
Model NO. AM-900B
Kind Surgical
Group All
Source Oxygen
Type of Operating Light Not
Size 10.4′′′′ime;′′′
Origin China
Type Ventilator
Certification CE, ISO13485
LCD Display With LCD Display
Anesthesia Semi Open Suction
Medical Device Regulatory Type Gxzz1234567890
Trademark AMISMED
HS Code 90192000
ICU Ventilator with CE approved (AM-900B) without/with Air Compressor
Ventilator AM-900B without Air Compressor
Microprocessor controlled, Pneumatically driven electronically controlled
10.4' TFT display screen for ventilation parametersmeters
Humidifier with temperature adjustment
With medical air compressor, built-in backup battery up to at least 4 hours
Applied for Adult and Pediatric
Main technical specifications:
Breathing Mode: A/C,SIPPV(VCV),IPPV(VCV),SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT,MANUAL
Tidal Volume: Adjustable range: 20~1500ml ; Display range: 0~2000ml
I/E Ratio: 4:1 ~ 1:4
Respiration Frequency : 1~99 bpm;
IMV Frequency : 1~20 bpm
Lung compliance: ≤30 mL / kPa kPa kPa
Maximum Minute ventilation: ≥18L / min min min
Pressure Limited: 1.0kPa~ 6.0kPa
PEEP: 0 ~ 1.0 kPa
Ptr: -1.0kPa~1.0kPa
Max .Safe Pressure: ≤6.0 kPa kPa kPa
Trigger Method: Pressure Trigger, Volume Trigger
Control Method: Pressure Control, Volume Control
Ventilation monitoring:
Tidal volume,Minute ventilation,Frequency, Airway Pressure, I/E, inspiration time, PEEP, FiO2, PCV,PSV
Waveform of time-airway Pressure and so on.
Ventilator AM-900B with Air Compressor
Microprocessor controlled, Pneumatically driven electronically controlled
10.4' TFT display screen for ventilation parametersmeters
Humidifier with temperature adjustment
With medical air compressor, built-in backup battery up to at least 4 hours
Applied for Adult and Pediatric
Main technical specifications:
Breathing Mode: A/C,SIPPV(VCV),IPPV(VCV),SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT,MANUAL
Tidal Volume: Adjustable range: 20~1500ml ; Display range: 0~2000ml
I/E Ratio: 4:1 ~ 1:4
Respiration Frequency : 1~99 bpm;
IMV Frequency : 1~20 bpm
Lung compliance: ≤30 mL / kPa kPa kPa
Oxygen Concentration: 21%~100%
Maximum Minute ventilation: ≥18L / min min min
Pressure Limited: 1.0kPa~ 6.0kPa
PEEP: 0 ~ 1.0 kPa
Ptr: -1.0kPa~1.0kPa
Max .Safe Pressure: ≤6.0 kPa kPa kPa
Trigger Method: Pressure Trigger, Volume Trigger
Control Method: Pressure Control, Volume Control
Ventilation monitoring:
Tidal volume,Minute ventilation,Frequency, Airway Pressure, I/E, inspiration time, PEEP, FiO2,PCV,PSV
Waveform of time-airway Pressure and so on.