Top Quality HX-102 Mobile X-ray Machine (For Radiography)

Top Quality HX-102 Mobile X-ray Machine (For Radiography)

2170 USD

add to cart
Model NO. HX-102
Type X Ray Equipment
Group All People
Medical Devices Reg./Record No. Sxzz20152300950
Power Output 3kw
Operation Method Wire /Wireless Control
Mas 1.0~160 Mas (45steps)
Tube Voltage 40~100kv (Interval 1kv)
Trademark healicom
Origin Jiangsu, China
Classification Imaging Diagnostic Equipment
Certification CE, ISO13485
Medical Device Regulatory Type Type 2
Certificate CE ISO
Frequency 25kHz
Fixed Anode Focus 2.6
Power Supply 220V±10% 50Hz;10% 50Hz10% 50Hz
Warranty 12 Months
Specification CE ISO
HS Code 9022140090



Introduction:
HX102 Mobile X-ray Equipment is a mobile X-ray imaging of medical diagnostic equipment. It meets human skull, chest, limbs and other parts of the X-ray photography requirements in the wards, operating rooms, emergency rooms and other occasions. Not only can be used as body X-rays, it can also do pet or wild animal X-ray examination.
Features:
1. The structure using ergonomic design, compact appearance, easy to operate;
2. Using high-pressure tube, kV, mA and quantity, film clarity, high contrast;
3. Using the combined X-ray generator, the tube can rotate freely up and down, up and down arm movement, project the patient may be at any angle, easier to use, wider range of applications;
4. With a light hand tune symmetrical medical X-ray collimator, the collimator size can be adjusted as needed, while using high intensity analog optical positioning, scale ranging, more accurate positioning, shooting and more convenient;
5. In the X-ray generator installation of protective lead, protect radiation to the surrounding environment, the operator of the radiation damage, and the machine can be wireless remote exposure more than 10 meters (also wired control);
6. The current third gear adjustable (15mA, 30 mA, 50 mA), can be selected, a wider range of applications of the instrument according to the requirements of different film;
7. Shockproof, anti-scatter, full-wave rectification;
8. Stable electrical performance, reliable, multiple protection, such as tube voltage, overvoltage, overcurrent tube current, output overload;
9. The inner telescopic vertical angle greater than 60 °°deg;°
Parameter
Power Output 3KW
Frequency 25KHz
X-ray Tube Fixed anode Focus 2.6
Tube Voltage 40~100KV (interval 1KV)
Tube Current 40~49KV 50mA 1~160 mAs
50~59KV 42mA 1~160 mAs
60~69KV 36mA 1~140 mAs
70~79KV 31mA 1~125 mAs
80~89KV 28mA 1~100 mAs
90~100KV 25mA 1~80 mAs
mAs 1.0~160 mAs (45steps)
Power Supply 220V±10% 50Hz inner-resistance≤1.0 Ωce≤1.0 Ω0 Ωce≤1.0 Ω
Operation Method Wire /Wireless control