| Model NO. | HX112E |
| Type | X Ray Equipment |
| Group | All |
| Medical Devices Reg./Record No. | Ssyjxzz20102300187 |
| Perspective Max Rated Capacity | Tube Current 8 Ma Tube Voltage 120 Kv |
| Certificate | CE ISO |
| Transport Package | Carton |
| Origin | Jiangsu, China |
| Classification | Imaging Diagnostic Equipment |
| Certification | CE, ISO13485 |
| Medical Device Regulatory Type | Type 2 |
| High Frequency Inverter Power Supply | Power:5.0kw Main Inverter Frequency: 40 kHz |
| Photography Tube Voltage, Ma, Mas | 40~120kv, 20~100mA, 1~180mas |
| Trademark | Healicom |
| Specification | CE, ISO |
| HS Code | 9018909090 |


| Category | Items | Content |
| Electrical performance | High frequency inverter power supply | Power:5.0kW Main inverter frequency: 40 kHz |
| Perspective max rated capacity | Tube current 8 mA Tube voltage 120 kv | |
| Automatic fluoroscopy | tube voltage 40 kv~120kv,adjust automatically tube current : 0.3mA~~4mA adjust automatically | |
| Manual fluoroscopy | tube voltage 40 kv~120kv, continuous tube current : 0.3mA~~4mA continuous | |
| Pulse fluoroscopy | tube voltage 40 kv~120kv, continuous tube current : 4.1mA~~8mA continuous | |
| Photography tube voltage, mA, mAs | 40~120KV, 20~100mA, 1~180mAs | |
| Plate holder size | 200mmx250mm(8'x10') or 250mmx300mm(10'x12')mm(10"x12");x12") | |
| X-ray tube | X-ray tube special for high frequency | large focus:1.5, mall focus :0.3 Anode thermal capacity: 35kJ (47 kHu) Tube thermal capacity: 650kJ (867 kHu) |
| Imaging system | Image intensifier | Imported 9 inch image intensifier |
| CCD photography | Imported ultra-low illumination CCD radiography | |
| Monitor | Center definition is 1000 lines and frequency for picture refresh is 75Hz. | |
| CCU (central control) | HD progressive output, continuous adjustable recursion, many images storage, upright image, horizontal image, positive & negative image, image patching, LIH(last image freeze), OSD (monitor display).lay).lay). | |
| Structure and performance | Direction wheel and main wheel | Direction wheel can rotate in any direction, and main wheel can rotate in ±90°.smn;90°.eg;.smn;90°. |
| C-arm | The up and down electrical stroke of pillar is 400mm. Monitor rotating angles ≥300°300°deg;300° Forward and backward movement:200mm; Revolution around horizontal axis : ±180°; Revolution around vertical axis: ±15°, distance from focus to screen: 960 mm; C-arm open distance: 760mm C-arm arc depth: 640mm; Slipping on orbit : 120°(+90°~-30°)orbit : 120°(+90°~-30°)g;~-30°)orbit : 120°(+90°~-30°) |
| New integrated C-arm mainframe | one set |
| Combined high-frequency high-voltage X-ray generator and high-frequency power supply(5.0kW, 40 kHz, 120kV) | one set |
| Imported 9 inch image intensifier | one set |
| Imported ultra-low illumination CCD radiography | one set |
| High-definition progressive output CCU control system | one set |
| High-definition progressive output CCU control system | one set |
| Imported dense grain grids | one set |
| Electrical adjustable beam limiting device | one set |
| 14-inch high-definition medical dedicated monitor | one set |
| Unique hand-held controller | one set |