| Model NO. | HX112D |
| Type | X Ray Equipment |
| Group | All |
| Medical Devices Reg./Record No. | Ssyjxzz20102300187 |
| Fluoroscopy Capacity | Tube Current:8mA Tube Voltage:110kv |
| Certificate | CE ISO |
| Specification | CE, ISO |
| HS Code | 9018909090 |
| Classification | Imaging Diagnostic Equipment |
| Certification | CE, ISO13485 |
| Medical Device Regulatory Type | Type 2 |
| Photography Capacity | 3.5kw |
| Photography Tube Voltage and Mas | 40 Kv~110 Kv 20-63mA 1-125mas |
| Trademark | Healicom |
| Origin | Jiangsu, China |


| Category | Project | Content |
| Electrical Performance | Photography Capacity | 3.5KW |
| Fluoroscopy Capacity | Tube current:8mA Tube Voltage:110KV | |
| Automatic Fluoroscopy | Tube Voltage:40kV~110kV automatical adjustment Tube Current:0.3mA~4mA automatical adjustment | |
| Manual Fluoroscopy | Tube Voltage:40kV~110kV Continuous Tube Current:0.3mA~4mA Continuous | |
| Pulse Fluoroscopy | Tube Voltage:40kV~110kV Continuous Tube Current:4.1mA~8mA Continuous | |
| Photography Tube Voltage and mAs | 40 kV~110 kV 20-63mA 1-125mAs | |
| film holder Size | 200mm×250mm(8″×10″)orPrime;×10″)or10″)orPrime;×10″)or 250mm×300mm(10″×12″)0″×12″);×12″)0″×12″) | |
| X-ray Tube | X-ray Tube Special for High Frequency | Fixed anode Dual-focus, small focus: 0.3, large focus:1.5 High Frequency Inverter: 40KHz thermal capacity 35KJ (47KHU) Tube thermal capacity 650KJ(867KHU) |
| Video System | Image Intensifier | TOSHIBA (9″) Image Intensifiernsifiernsifier |
| CCD Video camera | Ultra low-light CCD camera | |
| Monitor | Horizontal center resolution 1000/L, edge 800/L Visual bandwidth12.5MHz 50bit Image 75 f/s | |
| CCU main control | High Definition progressive output mode, 8 level Noise Reduction,8 image storage, Vertical Image, Horizontal image flip, positive or negative image | |
| Structure | Directive wheel and major wheel | Directive wheel 360° rotation, freely change the moving direction of the unit, major wheel ±90° rotation90° rotationtion90° rotation |
| C-arm | Electrical Ascending & Descend ≥400mmge;400mmge;400mm Monitor rotation ±135°smn;135°deg;smn;135° Forward and Backward Movement: 200mm Rotation around Horizontal Axis: ±180°usmn;180°eg;usmn;180° Rotation around Vertical Axis : ±15°usmn;15°deg;usmn;15° Focus screen distance:960mm C-arm opening: 760mm C-arm arc depth: 640mm? Slip on orbit: 120°(+90°~ -30°)g;~ -30°)eg;)g;~ -30°) |
| New integrated C-arm mainframe | one set |
| Combined high-frequency high-voltage X-ray generator and high-frequency power supply(3.5kW, 40 kHz, 110kV) | one set |
| Imported 9 inch image intensifier | one set |
| Imported ultra-low illumination CCD radiography | one set |
| High-definition progressive output CCU control system | one set |
| High-definition progressive output CCU control system | one set |
| Imported dense grain grids | one set |
| Electrical adjustable beam limiting device | one set |
| 14-inch high-definition medical dedicated monitor | one set |
| Unique hand-held controller | one set |