Specification: Parameters: Four Parameters: NIBP, Pulse Rate, SpO2, TEMP. Wave forms: SpO2 wave form Features: 1. Intelligent monitoring NIBP, SpO2, PR, Pulse Strength, PLETH and TEMP; 2. Bright and clear LED and LCD display; 3. Compact, light for handing and easy operation; 4. Audio and visual alarm when sensors off or alarm limit exceeded; 5. Storage and review of patient's NIBP data up to 900 groups and SpO2, TEMP trend data up to 3150 groups. The data is never lost even when power's off; 6. Three kinds of power supply, AC Power, Build-in rechargeable Li-ion battery and Common AA alkaline or rechargeable batteries; 7. Automatic shut down, shut down time adjustable from 2~15Min; 8. History data uploading to a personal computer for display, observing and printing; Applications: This model can be applied in the hospital's operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment. Standard Packing List: NIBP extension tube 1PC Adult NIBP cuff 1PC Adult SpO2 Sensor(include TEMP Probe) 1PC AC power adaptor 1PC Communication cable 1PC Selectable Accessory: Pediatric NIBP cuff Pediatric SpO2 sensor H. S. Code: 90181930 Dimension: 160mm× 148mm× 85mmm× 85mm; 85mmm× 85mm Net Weight: 565g Gross Weight: 980g Package Size: 245× 185× 100mm× 100mm 100mm× 100mm Technical specification Specifications: NIBP: Patient: Adult and Pediatric Measurement method: Oscillometric Range: Adult: 30mmHg~255mmHg Pediatric: 30mmHg~160mmHg Measurement unite: MmHg/kPa selectable Measurement mode: Manual, Auto, STAT Measurement Type: SYS, DIA, MAP Measurement interval in AUTO mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60Min Measuring period in STAT mode: 5 Min Resolution: 1mmHg Over-pressure protection: Adult: 300mmHg Pediatric: 220mmHg SpO2: Patient: Adult, child Range: 0 -100% Resolution: 1 % Accuracy: ± 2 %(90~99%), ± 3 %(70~89%), unspecified (, unspecified (< 70%)ecified (< 70%) PR: Range: 30bpm~250bpm Resolution: 1bpm Accuracy: ± 2bpmmn; 2bpmmn; 2bpm Environment: Temperature Operation: 0° C~45° C~45° C; C~45° C Transportation and storage: -20° C~60° C60° Cg; C60° C Humidity Operation: 15%~95 %( non-condensing) Transportation and storage: 10%~95% (non-condensing) Altitude Operation: 86kPa ~106kPa Transportation and storage: 50kPa~106kPa Power Requirements: AC power adaptor Input: AC 100~240V, 50/60Hz, 0.7A Output: DC 8.4V, 1A Internal battery Type: 1500mAh/7.2V Li-ion rechargeable battery Operating Time: 5 hours of stand-by time with a full battery. Recharge time: 8 hours