bargain
add to cart| Model NO. | BES307DT |
| Type | Digital EEG/ECG/EKG/EMG/VCG |
| Group | Animal |
| Medical Devices Reg./Record No. | Yssyjx20150068 |
| Input Circuit | Floating |
| Size | 285(W)*200(D)*50mm(H) |
| Input Circuit Current | <0.1ua0.1ua |
| Time Constant | > 3.2s |
| Gross Weight | 3.6 Kg |
| Transport Package | Cartons |
| Origin | Shenzhen |
| Classification | Physiological Functions of Diagnosis and Monitoring Equipment |
| Certification | CE, SGS, FDA, EEC, ISO13485 |
| Medical Device Regulatory Type | Type 2 |
| Lead | 12 Leads |
| a/D Converter | 12 Bits |
| Power Supply | 110-240V, 50/60Hz AC |
| Sampling Rate | 1000 Samples/Sec/Channel |
| Net Weight | 2.0kg |
| Trademark | BMV |
| Specification | CE, SGS |
| HS Code | 90181930 |

| Display | 7-inch color LCD display, resolution 480 × 800, synchronized display ECG waveform, time, heart rate, etc.e, etc.e, etc. |
| Lead | Standard 12 lead or European lead combination, 12 lead synchronous acquisition |
| safety class | IEC class CF type |
| Input method | Floating, defibrillation protection |
| Patient leakage current | <10μA10μA |
| Sampling Rate | 1000Hz per channel |
| Amplitude-frequency characteristics | 0.05 to 150 Hz |
| The time constant | ≥≥ge;≥3.2s |
| Common mode rejection ratio (CMRR) | ﹥ 100dB00dB |
| input resistance | ≥≥ge;≥50Mohm |
| Input loop current | ≤≤le;≤ 0.1μμmu;μA |
| Noise level | ≤≤le;≤15μμmu;μVp-p |
| Resistance to polarization | ±±plusmn;± 500mV |
| Calibration voltage | 1mV ± 2%usmn; 2%usmn; 2% |
| filter | AC (50Hz or 60Hz, -20dB) |
| EMG (25Hz / 35Hz / 45Hz / 75Hz / 100Hz, -3dB) | |
| Drift (0.5Hz, -3dB) | |
| 1.25, 2.5, 5, 10, 20, 40 mm / mV ± 2%usmn; 2%usmn; 2% | |
| Gain | Built-in high-resolution thermal printer (Y axis ≥≥ge;≥ 8 points / mm, X axis ≥≥ge;≥ 40 points / mm (paper speed 25mm / s)) |
| Printing system | 5,6.25,10,12.5,25,50 mm / s ± 3%usmn; 3%usmn; 3% |
| Paper speed | 80mm (width) × 15m (long) high-speed thermal paper or folding paperg paperg paper |
| Recording paper specifications power supply | AC 220V ± 10%, 50Hz ± 2%, 75VAlusmn; 2%, 75VAlusmn; 2%, 75VA |
| DC 12.5V 1800mA rechargeable lithium battery | |
| 2 Φ5x20mm 3.15A 250V 250V 250V | |
| Fuse specifications | Automatic; manual; single guide 1 minute compression record; rhythm analysis (R-R histogram and trend graph) |
| Operating mode | 3/2 Road; 3/2 + 1 Road; 3/3 Road; 3/3 + 1 Road |
| Print output Features | Automatic measurement of ECG parameters, automatic analysis |
| The machine can store about 200 cases of cases, support SD card mass storage | |
| Case demo, playback, print again, transfer SD card, delete, empty and so on | |
| Lead drop detection and indication | |
| Standard 10 electrode terminals | |
| 285 (length) × 200 (width) × 65mm (high); 65mm (high); 65mm (high) | |
| 2.1kg | |
| Lead line | 3.6kg |