Model NO. MY-F017
Max Power Output 400va
Baby Temperature Control Range 34-37 °c (Override Model: 37-37.5°c)7.5°c);c)7.5°c)
Trademark MAYA
Specification CE, ISO
Medical Devices Reg./Record No. Gsyjxzz20063410459
Air Temperature Control Range 25°c-37°c (Override Model: 37-38°c): 37-38°c);c): 37-38°c)
Operating at Temperature Equilibrium 90 Min(Set Temp 36 °c-Ambient 15 °c)15 °c);c)15 °c)
Transport Package Carton
Origin China

Feature:
1)Air mode and Baby mode controlled by micro-computer;
2)Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;
3)Set temperature, air temperature, baby temperature and internal battery voltage can be displayed separately;
4)Failure alarm indication;
5)Can be equipped with ≥37 ° temperature set functionfunctionfunction
6)Double wall Acrylic glass hood with side door so that thebassinet can be pulled out from it;
7)Natural air flow humidity;
8)The height of whole unit can be adjusted;
9)With Oxygen cylinder and Oxygen supply configuration;
10)Observation lamp.
Standard Configuration:
The hood,
the base,
the mobile cabinet,
the controller,
internal battery
observation lamp
oxygen cylinders
oxygen supply system
skin temperature sensor
I.V pole,
mattress
adjustable stand
Optional Configuration:
≥37°C override temperature modeure modeure mode
disposable skin temperature sensor
ambulance trolley
Specification:

AC Power supply

AC220V-230V/50HZ or AC110-120V/50-60Hz

DC Power supply

DC 12V/10A or DC 24v/6A

Max power output

400VA

Mode of control

Air mode and baby mode controlled by micro-computer

Air temperature control range

25°C-37°C-37°Ceg;C-37°C
(override model: 37-38°C)eg;C)eg;C)

Baby temperature control range

34-37 °Cdeg;Cdeg;C
(override model: 37-37.5°C)eg;C)eg;C)

Accuracy of skin temperature sensor

±0.3°Cmn;0.3°Ceg;Cmn;0.3°C

Temperature variability

≤ 1°C 1°Ceg;C 1°C

Temperature uniformity

≤ 1.5°C (mattress is on the horizontal position)osition)osition)

Inclination of the bassinet

± 12°smn; 12°deg;smn; 12°

Noise inside hood

≤52dB(A) (environment noise ≤ 45dB(A))5dB(A))5dB(A))

Failure alarm

Over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.

Operating at temperature equilibrium

90 min(set Temp 36 °C-Ambient 15 °C)5 °C)g;C)5 °C)

Environmental Temperature:
Operating range: 10°C -30°C-30°Ceg;C-30°C
(set temperature should be higher 3°C than the environment temperature)ture)ture)
Ambient air movement rate: ≤ 1.0 m/s m/s m/s
Package Information:
Packing: each unit is packed into two cartons
Packing size:
main body: 1095mm*655mm*755mm, G.W: 80kg
cabinet: 1380mm*610mm*390mm, G.W: 45kg