High frequency and pressure generator: Size: 600*420*650mm
v the high frequency multiple-pulse X ray generator is used for radio diagnosis, it ensures data and repetition's accuracy and shorten time of exposure.
v
v with the most professional and stable high frequency and pressure generator, it makes a high dose output,high power load and ultrahigh frequency contravariant which perfectly guarantees users' radiography quality. The generator is compatible with almost all good brands of tube in the world.
v it is equipped with APR/AEC which possess tube overload protection)
v the control functions of the generator are integrated in the system control center
v It can meet high frequency filming requirements since its rated voltage is with a high of 150KV
v 50KW large capacity makes a longer uninterrupted work
v perfect performance and stability
v it is complicated to set parameters for most of generators which lead to time wast. But our generator is equipped with easier parameters settings and firmwares updating programs.
v rotating anode's calorific capacity display and protection can prevent overheat of pipe shroud cause by overload.
v It stops the rotating anode by DC, it makes less noise after exposure.

Configuration parameter of the x-ray machine
NO. technical requirements
1 high frequency and pressure X ray generator for medical diagnostic use
1.1input power: 380V±38V,50Hz±1Hz.
1.2maximum power output :50 kW
1.3Photography tube voltage:it can be adjusted continuously, adjustable step width is 1KV,adjustable range: 40kV~150kV
1.4photography tube current:it can be adjusted by sections. Adjustable range: 10mA~630mA
1.5load time: adjustable range: 0.001-10sec
1.6current can be adjusted by sections. Adjustable range: 0.1mAs~500mAs
1.7working frequency: 100kHz
2X ray tube
2.1:highest peak tube voltage: 125kV
2.2maximum filament current's heat characteristic: big focus:5.4A, small focus:5.4A.
2.3focus: small focus:0.6mm;big focus:2.0mm
2.4Anode input power:small focus:18kw;big focus:50kw
2.5Anode optics angle: 14
2.6 rotate speed of Anode: 2800rmb
2.7Anode thermal capacity: 160kJ (220kHU)
2.8tube module thermal capacity: 1250KHU(900KJ)
3 Filming bed
3.1 length: 2200mm±10%
3.2 width: 750mm±10%
3.3 lengthways moving range of bed surface: 1000mm±10%
3.4 crosswise moving range of bed surface: 250mm±10%
3.5 bed surface locking pattern: electromagnetic lock(permanent magnet)
3.6 bed surface locking control: foot switch
3.7 breaking force: ≥100N
3.8 starting force:≤50N
3.9 load bearing of bed panel: 150kg
4stand column
4.1 height: 1920mm±10%
4.2 up-and-down moving range: 420mm-1810mm±10%
4.3 up-and-down moving range along the lathe bed: 2000mm±50mm
4.4 vertical lift range along the lathe bed: 430mm-1660mm±10%
4.5 left and right moving range of flat panel detector : 350mm±5%
4.6 X ray tube module's slewing range around the cross arm(power brake locking): 360°
4.7 X ray tube slewing range: 0° ±2° ~ ±90° ±2°
4.8 stand column slewing range: fixed
5beam-defining clipper
5.1 power supply: 24VAC,7A
5.2 inherent filtration : 2.0mmAL/75KVp
5.3 it is easy to turn on and off, flexible and reliable. It makes different sizes of rectangles exposure field in accordance with various requirements in practice.
6others
6.1high voltage cable:8m

Packing list

NO.naeunit
1. X ray tube holder one set
2. sternum standone set
3. filming bed one set
4. X ray tube one set
5. Beam-defining clipperone set
6. high frequency and pressure X ray generator for medical diagnostic use one set
7. operating consoleone set
8. high voltage cable two faculties