Aikai 3 C certification manufacturers production | a variety of low-voltage cabinet ggd soft start cabinet

Aikai 3 C certification manufacturers production | a variety of low-voltage cabinet ggd soft start cabinet

1+
7800 CNY (1135.71USD)
10+
7700 CNY (1121.15USD)
30+
7500 CNY (1092.02USD)

add to cart

Product parameters:

  • Processing customization: Yes
  • Brand: Eskai
  • Model: ASK-GCK
  • Structure: fixed
  • Protection class: ip30
  • Connection: fastener connection
  • Uses: suitable for generating units
  • Shape and installation: Floor type
  • Rated voltage: 0.38
  • Rated frequency: 50
  • Bus rated current: 630-6300
  • Rated insulation voltage: 100
  • Application scenario: Level 1 distribution
  • Material Number: 039
  • Product Certification: CCC
  • 3C Certificate No .: 2014010301737100



Sweep shop

Sweep the product

Soft-start cabinet main purposes:

1.Multi-start mode: current limiting start, harmonic start, harmonic current limiting start
2.
On the motor play a protective role
3.
Easy to operate
Soft start cabinet structure: Unique compact structure design, especially convenient for users to integrate into the existing system, for the user to save the cost of system transformation
Soft start cabinet range : Universal motor soft starter cabinet is a drag one, is a general type, there is an empty one soft start cabinet, one with a soft start cabinet, a two soft start cabinet, a three soft start cabinet
Soft start cabinet main technical parameters: Soft starter general parameters
1.
Control power supply AC220V , 50HZ
2.
Three-phase power AC380V , 50HZ
3.
Nominal current 15A-1000A , Total 22Rating
4.
Motor Power 7.5-530KW (Rated voltage380v)
5.
Applicable motor General squirrel cage induction motor
6.
Starting mode Harmonic current limiting2Ie-5Ie ) Voltage harmonics start-up (0.5-60Sec adjustable)
7.
Parking Free parking0.5-60Sec adjustable)
8.
Logic input2) impedance 1.8Kilohms, power supply 15Volts
9.
Relay output K1: Fault output; K2: Full voltage output (bypass) 'NO contact: 5A, 250VAC ''
10.
Starting frequency Can be used for frequent or infrequent start , Recommended not to exceed every hour 25Times
11.
Protective function Phase, overload, short circuit, SCR Protection, overheating and so on
12.
Protection level IP20
13.
cooling method Natural cooling or forced air cooling
14.
Installation method Wall-mounted
15.
Environmental conditions Ambient temperature: -25degree -45Degree, relative humidity less than 95% (15Degrees to 25Degree), no flammable, explosive, corrosive gases, no conductive dust, indoor installation, well ventilated; vibration less than 0.5G; Above sea level 2KM , Should be correspondingly reduced capacity use.