Product parameters:

![]() Sweep the shop | ![]() Sweep this product |
Brief introduction of diesel generator and cabinet
Diesel generators and cabinets are specially designed for parallel operation of two or more diesel generators; diesel generators and cabinets with self-power from the start, automatic synchronous parallel, automatic distribution of the load, automatically according to the load increase and decrease units , Automatic recovery of electricity, automatic cooling shutdown, automatic monitoring of diesel generator sets of power parameters, diesel generator sets fault display and protection and other functions.
Diesel generator and cabinet instructions:
Diesel generators and cabinets are mainly used for parallel operation of two or more diesel generating sets, diesel generating sets and cabinets with power from the start, automatic synchronization in parallel, automatic distribution of load, automatically according to load increase and decrease units, Automatic control of diesel generator power parameters, diesel generator fault display and protection and other functions; can effectively run parallel diesel generator sets, monitoring and protection; diesel generator as the main power supply when , Diesel generators and cabinets can reliably protect the normal operation of the distribution system; according to the size of the load distribution system load increase or decrease the number of units, so as to achieve energy saving, environmental protection effect; diesel generator running to maintenance time and faulty unit to be repaired , Diesel generators and cabinets can be rotated according to the need to maintain the operation of units; to protect the normal operation of the distribution system, diesel generator as a backup power supply, diesel generators and cabinets can automatically power off according to city power generators, automatic Closing and automatically start other units to run simultaneously, automatically allocate the load, automatically according to the load increase and decrease units, mains recovery automatic solution out, automatic cooling shutdown, effective and reliable protection of the normal operation of the distribution system.
Diesel generator sets and cabinets are mainly used for construction sites, real estate, banking, hospitals, shopping malls, mining, hotels, data centers and other fields.
Diesel generator and cabinet function
1Manual, automatic start unit running in parallel
2Power from the start
3Automatic synchronous operation
4Automatic load distribution
5Automatic increase and decrease units
6Automatic monitoring of diesel generator power parameters
Power generation projects:
Three phase voltage Ua , Ub , Uc unit: V
Three phase line voltage Uab , Ubc , Uca unit: V
Three - phase current Ia , Ib , Ic unit: A
frequency F1 unit: Hz
Split - phase active power PA , PB , PC unit: KW
Combined total Active power Ptotal unit: KW
Split - phase reactive power RA , RB , RC unit: Kvar
Combined total No use power Ptotal unit: Kvar
Apparent power SA, SB, and SC unit: KVA
Conjunction Apparent Total power Stotal unit: KVA
Phase power factor PF1, PF2, PF3
Average power factor Paverage
Accumulated active energy unit: KWh
Accumulated reactive energy unit: KVarh
Cumulative apparent energy unit: KVAh
Three-phase voltage phase sequence, phase angle detection
Busbar /City power project has:
Three phase voltage Ua , Ub , Uc unit:V
Three phase line voltage Uab , Ubc , Uca unit:V
frequency F1 unit : Hz
Three-phase voltage phase sequence, phase angle detection
The synchronization parameter entries are:
Power generation and busbars /Mains voltage detection
Power generation and busbars /Mains phase angle difference detection
Power generation and busbars /Mains frequency difference detection
The condition of power generation anomaly is:
The voltage is too high
The voltage is too low
Frequency is too high
Frequency is too low
Phase loss
Reverse phase sequence
Loss of power
Fault display and protection functions are available:
High water temperature warning
High water temperature shutdown alarm
Low oil pressure warning
Low oil pressure alarm
Overspeed shutdown alarm
Low fuel level warning
Startup battery voltage warning
Start-up battery low warning
Load over-current shutdown alarm
Start failure alarm
Shutdown failure alarm
Emergency shutdown alarm
Closing fault
Opening fault
Oil pressure sensor open circuit alarm
Reverse power
Reverse phase sequence
7Other optional features
Differential Protection
PLC Programmable Controllers
Grounding protection
Remote monitoring, communication
Diesel generator and cabinet structure
1High-quality cabinet
Cabinet using the national 3C standard cabinet GCK, GGD; can also be customized according to the requirements of non-standard high-quality cabinet.
2Parallel controller
Well-known at home and abroad controller (Dan control, deep-sea, Comay, Zhongzhi, Kai hearing, etc.)
Can be manual / automatic operation of diesel generators start, parallel; of diesel generators and power distribution system monitoring and protection
3breaker
Domestic and foreign well-known circuit breaker (ABB, Schneider, Mitsubishi, LG, Siemens, Changshu, Chint, West Germany,
Effective on the system points, closing, and protect the line.
4meter
Industry-renowned high-precision pointer instrument, intuitive display of current, voltage, frequency, power and power factor.
5Button and indicator
High-quality, good brand products (Schneider, Shanghai Second Engineering, Chint, etc.) its soft touch, bright colors, reliable performance.
6Relays
Use of domestic and international famous brands (OMRON , Schneider, etc.) its stable performance, beautiful appearance.
7Primary bus
The use of national standards Zinc copper, high-quality heat-shrinkable tube color.
Diesel Generators and Cabinets Ordering Information
1Model and specification of diesel generator set
2Need to know diesel generator power, voltage, current, frequency
3Diesel generators have automatic speed control, voltage regulator power
4DIESEL GENERATOR SET SPEED REGULATOR
5Diesel generator sets and cabinet cabinet size requirements
6Diesel generator sets and cabinet main circuit breaker brand, type, pole number, specifications
7Diesel generator and cabinet into the outlet mode
8Other diesel generators and cabinet requirements
For more information about diesel generator sets and cabinets, please contact us, thank you.
Service Tel 4006731288