The United States and Thailand original MCT200 thickness / coating / coating thickness / Mattel thickness

The United States and Thailand original MCT200 thickness / coating / coating thickness / Mattel thickness

5500 CNY (800.82USD)

add to cart

Product parameters:

  • Processing customization: No
  • Type: Ultrasonic Thickness Gauge
  • Brand: MiTeCH / Mattel
  • Model: MCT200
  • Measuring range: 0 ~ 1250μm


Mattel MCT200 coating thickness gauge

Measuring range: (0 ~ 1250) μm (F1, N1 probe), F10 probe up to 10mm

Indication accuracy: ± (3% H + 1) μm; H is the measured coating thickness

Communication storage: Can store 20 groups (up to 50 measurements per group) Measurement ss0064d data; communication interface USB1.1, can be connected with the PC, communication

Standby time: More than 200 hours (not open backlight)

Weight: 340g

Total Weight: 1.5KG

Dimensions: 125 mm x 67 mm x 31 mm

MCT200 Coating Thickness Gauge is a high-speed, non-destructive and precise coating (eg paint, coating), coating thickness measurement, film thickness measurement, widely used in the manufacturing industry, metal processing industry , Chemical industry, commodity inspection and other testing areas. 0-10 mm detection range, to meet the different industries for the workpiece surface coating thickness of the detection needs. Is to improve production efficiency and pass rate, saving production costs necessary professional precision instruments

Functional use

There are ten types of probes to choose from, the probe contact parts hard chrome plated or ruby, durable by selecting the appropriate probe, can measure the magnetic metal substrate on the non-magnetic coating thickness, but also non-magnetic metal The thickness of the non-conductive coating on the substrate
With the probe zero calibration, one point calibration, two-point calibration function, and basic calibration method can be used to probe the system error correction
There are two measurement methods: single measurement mode and continuous measurement mode
Has a measurement status prompt function
L EL backlight display, easy to use in low light conditions
Remaining battery indication function, real-time display battery remaining capacity
With automatic sleep, automatic shutdown and other power-saving features
With USB1.1 communication interface, the measured value can be transmitted to the PC
Can be equipped with computer software, with transmission measurement results, measured value storage management, statistical analysis of statistical values, print measurement reports and other rich features
Aluminum case, compact, portable, solid and durable, suitable for harsh operating environment, anti-vibration, shock and electromagnetic interference

working principle

The instrument uses magnetic and eddy current two thickness measurement method, can be measured without loss of magnetic metal (such as steel, iron, nickel, alloy and hard magnetic steel, etc.) on the base of non-magnetic coating thickness (such as aluminum, (Such as enamel, rubber, paint, etc.), and non-magnetic metal matrix (such as copper, aluminum, stainless steel, zinc, tin, etc.) on the thickness of non-conductive coating (such as: enamel, rubber, paint,

Working conditions

Ambient temperature: Operating temperature - 20 ℃ ~ +50 ℃ Storage temperature: -30 ℃ ~ +70 ℃
Relative humidity ≤ 90%
The surrounding environment without strong vibration, no strong magnetic field, no corrosive media and serious dust

Instrument characteristics

There are five probe types to choose from, the probe contact parts using hard chrome plated or ruby ​​materials carefully developed, durable
By selecting the appropriate probe, it is possible to measure both the thickness of the non-magnetic coating on the magnetic metal substrate and the thickness of the non-conductive coating on the non-magnetic metal substrate
With the probe zero calibration, one-point calibration, two-point calibration function, and the basic calibration method can be used to probe the system error correction
There are two measurement methods: single measurement mode and continuous measurement mode
Has a measurement status prompt function
EL backlight display, can be easily used in dimly lit environments
With the remaining capacity indicator, real-time display battery remaining capacity
With automatic sleep, automatic shutdown and other power-saving features
With USB1.1 communication interface, can communicate with the computer Data processing software can be equipped with options, the results will be transmitted to the computer to achieve the measurement of storage management, statistical analysis, print reports and other functions
Compact, portable, durable, suitable for harsh operating environments, vibration, shock and electromagnetic interference

Operating methods and precautions

Operation method is
When the instrument is off, press and hold the CAL key and then press the key until the sound is on, and the calibration mark 'CAL' appears on the screen to enter the basic calibration status
The calibration can be repeated several times to improve the accuracy of the calibration
In the thinnest standard on the standard measurement, use the up and down keys to correct the reading, so that it reaches the nominal value of this standard. Then press the CAL key to enter the next standard piece of measurement calibration
Repeat the previous step in the order of increasing thickness using the other four standard sheets, each of which should be at least 1.2 times the thickness of the previous one, ideally two times, for example 50, 100, 200, 400, 800μm. The maximum should be close to but below the maximum measuring range of the probe; Note: Each thickness should be at least 1.2 times the thickness of the previous one.
After entering 5 calibration values, the instrument automatically shuts down and the new calibration value is stored in the memory of the probe. When the instrument is switched on again, the instrument will operate according to the new calibration value.
Avoid placing the instrument in a humid environment
Plug the probe, you should hold the active jacket along the axis force, can not rotate the probe, so as not to damage the probe cable core
Oil, dust adhesion will make the probe line gradually aging, fracture, after use should remove the dirt on the cable

Maintenance and maintenance of the instrument

When the battery capacity is close to running out, the battery should be replaced in time to avoid affecting the measurement accuracy.When the instrument is not used for a long time, the battery should be removed to avoid leakage of the battery, corrosion of the instrument box and electrode.
CAUTION Positive and negative polarity when the battery is installed! Polarity may cause damage to the instrument
Maintenance of zero matrix
The surface condition of the zero-matrix matrix has a great effect on the zeroing of the probe, so please pay attention to protect the zero-matrix to prevent surface scratches, rust
Alcohol, diluent, and so on the case, especially the window has a corrosive effect, so cleaning, with a small amount of water can be gently wipe