Product parameters:
XP-702IIZ leak detection
Features
We carry 25Year performance, high sensitivity, Small power of the hotline type semiconductor sensor (has applied for a patent ) PREFIX = O
Automatic zero adjustment without manual zeroing.
1A switch can be determined.
The power supply used is 5No. batteries 3Section, less than the original old 1Achieved lower operating costs and industrial waste.
When the battery is low, the pump or sensor is faulted with an alarm.
Filter exchange easier than the old. Maintenance efficiency greatly improved.
The use of accidentally sucked into the water, the pump will automatically stop to prevent the failure caused by water.
Anti-drip constructionJIS C 0920), It is possible to prevent malfunction due to rain.
Technical Parameters
model | XP-702IIZ-B | XP-702IIZ-A | XP-702IIZ-F |
Target gas X1 | A flammable gas (Natural gas, liquefied petroleum gas) | Two types of flammable gas switching | Instead of flon gas and flammable gas switching |
Detection principle | Hotline type semiconductor type | ||
Response time | 3 (Except freon gas) | ||
The amount of leakage that can be detected | Natural gas, liquefied petroleum gas Wait : 3 × 10-6 Pam3 /s Freon: ' R-407C ] 12.4g/ Leaked during the year ; [ R-410A ] 11.2g/ Leaked during the year | ||
Alarm mode | A disconnection alarm sound is emitted, and the alarm lamp flashes | ||
Explosion - proof structure | sensor : Pressure explosion-proof structure other : Intrinsically safe explosion-proof construction Exibd IIBT3 | ||
Use of the environment | -20~ 50° C, 30~ 90% RH the following ( But not condensation) | ||
power supply | 5Alkaline batteries 3Section | ||
usage time X2 | approximately 18Hour (alkaline batteries) | ||
Dimensions | W60RespectivelyH140× D40㎜ (excluding the protruding part) | ||
weight | approximately 260g (Without battery) | ||
Standard accessories | Sewage filters, filters, check the gas, dust filter, rubber caps, 5No. batteries 3Section, lanyard | ||
Optional products X3 | Road gas traps, telescopic gas into the tube, headphones, and so on | ||
※1Please contact us about the type of gas to be tested.
※2Different environmental conditions, conditions of use, shelf life, battery manufacturers, and sometimes different.
* 3have 4Gas traps, please contact us for details.