Light high current generator 1000a | manufacturers

Light high current generator 1000a | manufacturers

3500 CNY (509.61USD)

add to cart

Product parameters:

  • Customization: Yes
  • Type: digital current measuring instruments
  • Brand: Yu De
  • Model: YD
  • Measuring range: 50-10000
  • Accuracy: 0.01
  • Power: 1
  • Power supply voltage: 220V ± 10% 50HZ
  • Dimensions: 1






product description:

YD Portable high current generator Is based on the power sector and industrial and mining enterprises in the electrical equipment test, such as: a variety of switches, current transformers and other electrical equipment for current load test and temperature test and specially designed and manufactured special equipment.
This product is small size, light weight using one-piece structure, with the output current Promise adjustment, current rise and balance, load range, 0.5Level current transformer, digital display, beautiful appearance, reliable, easy to operate, safe, etc. It is an ideal equipment for industrial and mining enterprises to carry out riser or temperature rise test.

Technical Parameters

1, The riser rated capacity: KVA

2, the regulator rated capacity: KVA

3, Input rated voltage: 220V

4, Input rated current: 22.7A

5, The output rated current: 1000A

6, The output rated voltage: 5V

7, The impedance voltage: <8%

8, No-load current: <6%

9, Structure: one

working principle:

1, the instrument must have a good grounding.

2, Press the power supply, turn on the switch, the red indicator light, then the output side of the test object connection, press the start button, green light, then the riser waiting for the rise.

3, Clockwise evenly rotate the regulator, pay attention to the output current on the console to indicate the required high current.

4, The test process, once found abnormal phenomenon, should immediately cut off the power, identify the cause and then test.

5, The test is completed, the regulator must be zero, press the stop button to cut off the power, cut off the power , Can be removed before the test wiring to ensure safety.

Precautions:

1, The new installation and a long time do not have the transformer, run before use 1500The megger measures the insulation resistance between the coils and the coil to ground, and the resistance is not less than 0.5Megohm can only use.

2, The use of the riser and the console must be reliably grounded to ensure safety.

3, Should be used slowly and even up the flow, handling should avoid excessive vibration.

4, The regulator and brush contact surface should be kept clean, as the case may be 90%Alcohol dipped in cotton yarn wipe clean.
5
, The equipment should be placed in a clean, ventilated, dry and indoor preservation.

Equipment integrity:

1, Upstream Transformers One

2, Product certification A copy of

3, Instruction Manual A copy of

4, experiment report A copy of