Product parameters:

| Enter the order Yuan serial number | Tuning capacitor range | Sensitivity (PC) (Unbalanced circuit) | Allow current rms | |
| Unbalanced circuit | Balance circuit | |||
| 3 | 100 ~ 400 ~ 1500PF | 0.06 | 120mA | 1A |
(D), power frequency without halo test transformer
Model: YWDT-50/250
Rated capacity: 50kVA
Rated input voltage: 0.38kV Rated input current: 131.6A
Rated output voltage: 250kV Rated output current: 0.2A
Measuring winding voltage: 250V
Connection group: II0 Cooling method: ONAN
Allowed running time: 100% U N,IN Run for 60min
70% UN,IN continue to operate
Number of phases: single phase frequency: 50Hz
Partial discharge: 100% U N ≤ 5PC
Product structure: vacuum cast epoxy cylinder type
(5), no PD protection resistor
The protection resistor is connected between the test transformer and the voltage dividing capacitor to limit the short circuit current during the flashover of the test product, to protect the test product and to test the transformer.
Structure for the insulation tube skeleton, wire winding, both ends are equipped with pressure ring.
Model: RD-250-0.2
Rated voltage: 250kV
Rated current: 0.2A
Resistance: 4kΩ
Running time: 1h
Temperature rise: rated conditions of operation, the resistance surface temperature rise is not greater than 55K.
(6), no partial discharge capacitor voltage divider (and coupling capacitor)
Model: FOF-250-400
Rated voltage: 250kV
High voltage arm capacity: 400pF
Nominal divider ratio: 1000: 1
Capacitor at rated voltage U NCan be run continuously for 1 hour
Capacitor dielectric loss tangent: at 20 ° CN, 0.9 - 1.1U NNo more than 0.002
Capacitor short-time power frequency withstand voltage of 1.1UN
Capacitor in the nominal value of 100% of the voltage under the partial discharge is not greater than 5PC
Dielectric loss: ≤0.5%
Measurement accuracy: ≤ ± 1%
(Seven), electric filter pressure regulator
1, electric column regulator (built in the electric filter regulator device)
Model: TEDG-50
Rated capacity: 50kVA
Rated voltage: Input: 0.38kV Output: 0-0.42kV
Rated current: Input: 131.6A Output: 119.0A
Number of phases: single phase frequency: 50Hz
Cooling method: dry from the cold
Waveform distortion rate: ≤3%
2, power isolation filter (built in the electric filter regulator device)
The device consists of triple electrostatic shielded high voltage isolation transformer and high quality low-pass filter, the partial discharge detector used in the band can guarantee a 60dB attenuation effect.
Rated capacity: 50kVA
Rated input voltage: 0.38kV Rated input current: 131.6A
Rated output voltage: 0.38kV Rated output current: 131.6A
Number of phases: single phase frequency: 50Hz
Attenuation characteristics: 10kHz-1MHz ≥ 20-60dB
Cooling method: natural cooling
(8), power frequency high voltage test console
Power frequency high voltage test console and voltage divider, column regulator and so on to form a complete set of test equipment control, measurement and protection system.Through the operation instruction to complete the test items under the conditions of all the test procedures, and test the test Voltage, current or other parameters, pressure delay can be adjusted in the range of 0-99hr time interval, supporting the instrument measurement accuracy error is less than ± 1%, the protection system can be high frequency power test overload, overcurrent, Short circuit, flashover and other abnormal conditions for effective protection.
Model: YXY-2003
Rated capacity: 50kVA Rated voltage: 380V
Fourth, the use of the entire equipment conditions
1, the use of regional altitude of not more than 1000m
2, ambient air temperature range of -25 ~ +45 ℃
3, the ambient air relative humidity should not be greater than 80% RH
4, does not contain chemical corrosive gases and steam
5, no conductive dust and explosion hazard
6, no severe vibration and shock
7, indoor use
8, the grounding screw on the box to be reliable grounding, grounding resistance of the ground is not greater than 1Ω
9, test cable recommended with no halo wire