product description
The high-voltage circuit breaker is responsible for the double task of control and protection in the power system. Mechanical characteristics tester, is my company based on the latest "high voltage AC circuit breaker" GB1984-2003 design blueprint, with reference to the People's Republic of China power industry standard "high voltage test equipment common technical conditions" Part 3, DL / T846.3- 2004 high-voltage switch integrated tester for the design basis for the various types of circuit breaker dynamic analysis provides a convenient, able to accurately measure a variety of voltage levels of less oil, oil, vacuum, sulfur hexafluoride and other high-voltage circuit breaker machinery Dynamic characteristic parameter.
Features
2.1 test function
(1) joint (sub) gate sequence (12) over the trip
(2) joint (sub) gate maximum time (13) over the trip
(3) three-phase different period (14) just the (sub) speed
(4) the same phase (15) the maximum speed
(5) Joint (minutes) Gate time (16) Average speed
(6) action time (17) gold short time
(7) Bounce time (18) No flow time
(8) Bounce frequency (19) Current waveform curve (dynamic)
(9) Bounce width (20) Time travel speed Dynamic curve (ms)
(10) Stroke (21) Time Speed Stroke Dynamic Curve (mm)
(11) from the distance
Units are: time ms speed m / s distance mm
2.2 Features
(1) can do electric operation and manual operation;
(2) to adapt to 500KV voltage level within a variety of high-voltage circuit breaker mechanical dynamic test;
(3) measurable travel and custom travel;
(4) to achieve the circuit breaker of the single, single points, points, coincidence, re-operation;
(5) Wiring is simple, easy to operate, only one operation (sub) action can be combined (points) all the data, you can choose to save 50 sets of data, provide late query, but also on-site access to print all data and sports Graph;
(6) the use of Chinese characters prompted to man-machine dialogue mode of operation;
(7) data accuracy, strong anti-interference, small size, light weight, beautiful and generous;
(8) machine equipped with a clock circuit that can display the current year, month, day, hour, minute, second, even if the power, but also automatically save the settings data and test data;
(9) machine with a delay protection function, the circuit breaker action can automatically cut off the action power, a good protection of the circuit breaker equipment and high voltage switch tester;
(10) Instrument built-in DC power supply, selectable range: 30-270V / 10A, there is no conventional rectifier power output instantaneous voltage drop, to test the switch action voltage is very accurate;
(11) can dynamically analyze the relationship between the travel and speed of the circuit breaker every 1ms;
(12) display backlight using keyboard operation, the user can choose their own brightness.
Technical indicators
Environmental group: belong to GB6587.1-1986 "electronic measuring instrument environmental test master" in the Ш group of instruments.
Type: Portable Packing: Aluminum Box
Size and weight:
Host: 440 × 300 × 150 (mm) 5 (kg)
Accessories: 440 × 300 × 80 (mm) 3 (kg)
Working power: AC220V ± 10% Frequency: 50Hz ± 5%
Ambient temperature: -10 ° C ~ 50 ° C Relative humidity: ≤ 90%
Insulation resistance: ≤2MΩ
Dielectric strength: power into the chassis can withstand 1.5KV 1 minute pressure test.
Time test range: 1 ~ 499.9ms Resolution: 0.01ms Accuracy ≤ 0.1ms
Speed test range: 15m / s Resolution: 0.01m / s Accuracy ± 1% of reading +2 words
Stroke test range: unlimited resolution: 0.01mm accuracy ± 1% of the reading +2 words
DC power supply Select range: 25-265V / 10A Resolution: 1V: Accuracy ≤ ± 1%
Term Definition
1. Time:
From the moment to the joint (sub) gate instructions to play all the pole contacts are (separate) instantaneous time interval
2. Synchronicity:
The maximum time difference between the contact (separation) of the contact between the cutouts.
Bounce time
Switch the movable contact and the stationary contact in the closing (sub) gate operation, from the first close (separate) to the last stable to close (separate) time.
4. Operation time: (contact action time)
From the received (sub) gate instructions instantly play the moment just touch the moment.
5. Bounce times:
Switch the movable contact and the static contact in the sub (joint) gate operation, the number of separate (closed).
6. Bounce range:
The maximum bounce value of the movable contact during the movement of the movable contact.
7. Stroke:
Minute, closing operation, the distance between the starting position of the switch moving contact and the position of any one of the positions.
8. Open distance:
The total clearance between the contacts of the switch and any of the conductive parts connected thereto.
9. Super-trip:
Closing operation, the switch contacts contact the moving contact to continue the movement of the distance.
10. Travel:
Points, closing operation, the switch movement of the movement during the maximum stroke and the stability of the distance after the difference.
11. just the (minutes) speed:
Switch joint (sub) gate process, the movable contact and the static contact contact (separation) instantaneous movement speed
12. Average speed: switch together (sub) gate operation, the dynamic contact in the course of the movement of the stroke and the ratio of time.
13. gold short time:
In the combined operation, the time interval is separated from the moment when all the contacts are in contact with each other.
Sensor selection
7.1 linear resistance sensor (CWY30-2K type) linear displacement: 1-33mm
Applicable to: Vacuum circuit breakers
Distance range: <33mm error: 0.1mm
Speed: ≥5m / s Error: 0.1m / s
7.2 Angle displacement sensor (WDS65-1K type)
Applicable to: SF6 circuit breaker angular displacement: 350o
Distance range: Custom resolution: 0.1o
Speed: ≥15m / s Resolution: 0.1%
7.3 Auxiliary contacts
Auxiliary contact installation:
(1) auxiliary contact; must be installed in the switch on the moving end of the mouth or in the switch on the movable end of the trigger.
(2) the role of auxiliary contacts; is used to record the closing start and sub-gate of the time.
7.4 Points to note when installing:
(1) the contact between the axis of contact and the axis of the coaxial axis error ≤ 0.2mm.
(2) try to use the middle position of the sensor to determine the location of the contact, so that the movement of the moving stroke included in the stroke of the slider, so that the slider up and down when leaving a buffer margin.
(3) the installation to be tight and reliable, in the test so that the sensor body and the switch body can not produce relative displacement.
(4) sensors are precision electronic equipment, all parts must pay attention to waterproof and dustproof, try to keep dry and clean.
Product of the package
12. 1 high-voltage switch dynamic characteristics of a tester host
12. 2 high-voltage switch dynamic characteristics of the tester accessories
(1) linear sensor, angle sensor 1 set
(2) 1 set of sensor mounting bracket
(3) a power cord
(4) Fracture signal line 2 root
(5) combined signal line 1 root
(6) paper 2 rolls
(7) Fuse (5A) 2
(8) Product manual 1 this
(9) 1 warranty card
(10) 1 certificate