Supply transformer performance test bench
| 1+ | 29000 CNY (4222.49USD) |
| 52+ | 28000 CNY (4076.88USD) |
add to cart
Product parameters:
- Customization: Yes
- Brand: Yu De
- Model: YD
- Type: Multi-parameter tester
- Measuring range: 1
- Accuracy: 2
- Instrument size: 1500X80X1600
- Scope of application: 3
- Instrument weight: 60
- Power supply: 220
- Specifications: 4
Transformer characteristics of the integrated test bench is based on user needs will be transformer no-load short-circuit tester, variable than the group tester, inductive load DC resistanceTester, electric voltage regulator, etc. It can measure the transformer no-load current, no load loss, short circuit loss, impedance and other parameters, but alsoMeasuring transformer DC resistance, transformer ratio, variable ratio error, wiring group, etc. If the test transformer with external, but also for AC voltage test. Technical parameters of transformer integrated test bench No load, short circuit test, with the measurement parameters can be synchronized sampling, to avoid the meter and the reading is not synchronized caused by the error. First, the transformer integrated test bench Test object: The integrated test bench can test the capacity of 1600KVA and below the voltage of 10KV / 400V single three-phase distribution transformer. Second, the transformer integrated test bench Test items: 1, transformer DC resistance test2, transformer variable ratio test3, the transformer empty load characteristics test4, transformer pressure testThird, the transformer main test bench main technical parameters Input voltage: AC380V (three-phase five-wire) Rated current: 100A(A) transformer DC resistance tester GZY-10A1, the working power: AC220V ± 10%, 50Hz ± 5Hz sine wave2, the output current: 1A, 5A, 10A3, the test range: 1mΩ ~ 200Ω4, accuracy: 0.2% ± 3d5, resolution: 1μΩ6, the working temperature: 0 ~ 40 ℃7, the ambient humidity: ≤ 85% RH, no condensation(B) transformer variable ratio automatic tester BBY-D1, the working power: AC 220V ± 10% 50Hz ± 5% sine wave2, the test range: <1> Change ratio: 1-10000<2> Group: 1-123, Accuracy: 1-1000 (0.2% ± 2d), 1000-10000 (0.5% ± 3d)4, the working temperature: 0 ℃ -40 ℃5, the ambient humidity: <80%, no condensation(3) transformer empty load loss tester BKF-Ⅲ1, the work of power: AC220V ± 10% 50HZ ± 5% sine wave2, the measurement range: voltage: 0-600V (wide range, do not switch gear) Current: 0-60A, 6A (two range)3, accuracy: voltage, current, frequency 0.2% ± 2dPower 0.5% ± 2d (CosΦ> 0.1)1.0% ± 3d (0.02< CosΦ≤0.1)4, the working temperature: - 10 ℃ ~ +40 ℃5, the ambient humidity: 10% -80%6, the measurement results stored: 250 groupsPower frequency withstand voltage, induction voltage capacity and voltage can be customized according to customer requirements. The integrated console can be designed and manufactured according to the requirements of users.