Product parameters:

High current generator is based on the power sector and industrial and mining enterprises in the electrical equipment test such as: a variety of switches, current transformers and other electrical equipment for current load test and temperature test and specially designed and manufactured specialized equipment.
This series of products depending on the product size, weight using split / integrated structure, with the output current stepless adjustment, current rise and fall balance, load range, reliable, easy operation, security and other characteristics of industrial and mining enterprises to rise or temperature L test the ideal equipment.
two, The main technical parameters
Model | Rated Capacity | Rated input | Rated output | Impedance voltage | No-load current | structure | |||
Regulator | Riser | Current | Voltage | Current | Voltage | ||||
SLQ-5/1000 | 5 | 5 | 22.7 | 220 | 0.5/1 | 10/5 | < 8 | < 6 | One body / split |
SLQ-10/2000 | 10 | 10 | 26.3 | 380 | 1/2 | 10/5 | < 8 | < 6 | Split |
SLQ-20/4000 | 20 | 20 | 52.6 | 380 | 2/4 | 10/5 | < 8 | < 6 | Split |
SLQ-25/5000 | 25 | 25 | 65.8 | 380 | 2.5/5 | 10/5 | < 8 | < 6 | Split |
SLQ-50/10000 | 50 | 50 | 125 | 400 | 5/10 | 10/5 | < 8 | < 6 | Split |
Note: 'Nominal output', the left is in series; the right side of the output parameters for the parallel.
three, Use the environment
1, the working power: 220V / 380V ± 10% 50HZ
2, ambient temperature: -10 ℃ ~ 40 ℃
3, the product should be around the serious impact of transformer insulation gas vapor, chemical deposition of dust, dirt and other explosive media sites.
four, working principle
This series of products connected to the power supply, by adjusting the regulator output voltage to obtain the test required high current. The working principle is as follows: